AIM: Precise targeting is essential for adequate treatment of lesions during image-guided therapy. The aim of this study was to compare the performance of two emerging image-guided targeting technologies in a phantom model. MATERIALS AND METHODS: A computer-assisted navigation system and AcuBot were tested using three operators: an interventional radiologist and two endourologists. Fiducials were placed in an anatomic gelatin phantom and targeted by both systems. The images were reconstructed and analyzed using a specialized software package (Amira; Visage Imaging, Carlsbad, CA). Accuracy was assessed by measuring proximity of the tip of the needle to the fiducial on computed-tomography-guided imaging. Accuracy and time to target were quantified and compared. RESULTS: The mean distance from the desired target for AcuBot was 1.2 mm (range: 0.39-2.82). The mean distance from the desired target for the navigation system was 5.8 mm (range: 1.8-11.9). The AcuBot was significantly more accurate than the navigation system (p < 0.0001). The mean time from target acquisition to needle placement was 37 seconds (range: 15-75) for the AcuBot and 108 seconds (range: 45-315) for the navigation system (p = 0.001). CONCLUSION: Emerging technologies hold promise for increased accuracy during percutaneous targeted procedures. Both the AcuBot and the computer-assisted navigation system were accurate and efficient in a phantom targeting model. AcuBot was significantly more accurate, faster, and less user dependent than the navigation system. Further studies in animal and clinical studies are warranted to further advance this promising technology.
机译:目的:精确定位对于在影像引导疗法中对病变进行充分治疗至关重要。这项研究的目的是在幻像模型中比较两种新兴的图像引导瞄准技术的性能。材料与方法:使用三个操作员对计算机辅助导航系统和AcuBot进行了测试:介入放射科医生和两名内分泌科医生。将基准放置在解剖明胶体模中,并以两个系统为目标。使用专用软件包(Amira; Visage Imaging,加利福尼亚州卡尔斯巴德)重建和分析图像。通过在计算机断层扫描引导的成像上测量针尖与基准点的接近度来评估准确性。定量和达到目标的时间进行了量化和比较。结果:距目标目标AcuBot的平均距离为1.2毫米(范围:0.39-2.82)。距导航系统所需目标的平均距离为5.8毫米(范围:1.8-11.9)。 AcuBot比导航系统准确得多(p <0.0001)。对于AcuBot,从目标获取到放置针头的平均时间为37秒(范围:15-75),而导航系统的平均时间为108秒(范围:45-315)(p = 0.001)。结论:新兴技术有望在经皮靶向手​​术中提高准确性。在幻影瞄准模型中,AcuBot和计算机辅助导航系统都是准确而高效的。与导航系统相比,AcuBot的准确性,速度和用户依赖性大大降低。有必要在动物和临床研究中进行进一步研究,以进一步推动这一有前途的技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号