Purpose: To compare tip temperatures of the vibrating blades of the newer-generation Harmonic Ace device and the older-generation Ultracision Harmonic Scalpel LCS-K5. Materials and Methods: Comparison of two different harmonic scalpel blades was performed by applying them to 3-mm strips of raw chicken breast at room temperature and measuring the temperature of the tip of the vibrating blade at 0.5-second intervals using a thermocouple. Following activation, the tip was allowed to passively cool to 30 degrees C each time before reactivation. Each device was tested at power settings of 3 and 5 after activation for 1 to 5 seconds. All measurements were performed 5 times. Results: Compared to the older-generation Ultracision Harmonic Scalpel LCS-K5, the newer-generation Harmonic Ace was associated with higher tip temperatures at power level 5 at all times of activation (1-5 seconds), and at power level 3 at longer times of activation (3-5 seconds). The Harmonic Ace also takes longer to reach peak temperatures and can maintain blade hyperthermia for a longer period after activation for more than 3 seconds at power levels 3 and 5. Conclusion: The newer-generation Harmonic Ace may be potentially more effective in tissue dissection, but is associated with greater increases in peak temperatures and longer blade hyperthermia periods compared to the older-generation Ultracision Harmonic Scalpel LCS-K5. The difference is greater after longer periods of activation, and this may have more potential for collateral damage, particularly to nerves and bowel.
机译:目的:比较新一代Harmonic Ace设备和较早版本的Ultracision Harmonic Sc​​alpel LCS-K5振动刀片的尖端温度。材料和方法:比较两个不同的谐波手术刀刀片,方法是在室温下将它们应用到3毫米的生鸡胸肉条上,并使用热电偶以0.5秒的间隔测量振动刀片的尖端温度。激活后,每次重新激活前,使尖端被动冷却至30摄氏度。激活1到5秒后,以3和5的功率设置对每个设备进行测试。所有测量进行5次。结果:与上一代的Ultracision Harmonic Sc​​alpel LCS-K5相比,新一代的Harmonic Ace在所有激活时间(1-5秒)处在功率等级5时具有较高的烙铁头温度,而在更长的功率等级3时具有更高的烙铁头温度。激活时间(3-5秒)。 Harmonic Ace还需要更长的时间才能达到峰值温度,并且在功率等级3和5激活后可以保持刀片热疗更长的时间超过3秒。结论:新一代Harmonic Ace在组织解剖中可能更有效,但与上一代的Ultracision Harmonic Sc​​alpel LCS-K5相比,峰值温度升高幅度更大,叶片热疗时间更长。激活时间越长,差异越大,这可能有更大的潜在附带损害,特别是对神经和肠的损害。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号