STUDY OBJECTIVES: In this study, blood samples from ED patients that were delivered to the laboratory by a pneumatic tube delivery system and by a human courier were compared for timeliness and quality of results. METHODS: We studied all consecutive measurements of serum hemoglobin and potassium ordered from 2 emergency departments of a multisite tertiary care hospital system, one with a pneumatic tube system and the other using human couriers. Turnaround time was measured from the time that the test was ordered by the physician to the time the result was reported on the hospital information system. Hemolysis was measured with use of a standardized, validated method. ANALYSIS: Times were normalized by log transformation (ln [minutes + 1]), and a comparison of sites was conducted using analysis of variance. Hemolysis rates of the 2 delivery systems were compared by chi2. RESULTS: There was no significant difference in hemolysis rate between the 2 methods of delivery (7/121 [5.79%] with a pneumatic tube system and 20/200 [10%] with a human courier). When delivered with a pneumatic tube system, the mean turnaround times (with ranges) for both hemoglobin (33 minutes [4-230]) and potassium (64 [34-208]) were shorter than those delivered by a human courier (43 minutes [3-150] and 72 [28-213], respectively). CONCLUSION: The use of a pneumatic tube delivery system for transporting blood samples from the emergency department to the laboratory can significantly reduce the turnaround times of results without a reduction in sample quality.
机译:研究目的:在本研究中,比较了通过气管输送系统和人工运送到实验室的ED患者的血液样本的及时性和结果质量。方法:我们研究了从多站点三级护理医院系统的两个急诊部门订购的所有连续的血清血红蛋白和钾的测量结果,一个使用气动管系统,另一个使用人工快递员。从医生下令测试的时间到在医院信息系统上报告结果的时间,计算周转时间。使用标准的,经过验证的方法测量溶血率。分析:通过对数转换(ln [分钟+ 1])对时间进行归一化,并使用方差分析对位点进行比较。通过chi2比较2种递送系统的溶血率。结果:两种分娩方法之间的溶血率没有显着差异(使用气动管系统时为7/121 [5.79%],使用人工快递时为20/200 [10%])。使用气动管系统交付时,血红蛋白(33分钟[4-230])和钾(64 [34-208])的平均周转时间(有范围)比人类快递员(43分钟)要短[3-150]和72 [28-213])。结论:使用气管输送系统将血液样品从急诊室运送到实验室可以显着减少结果的周转时间,而不会降低样品质量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号