首页> 外文期刊>Journal of Electrostatics >Simultaneous removal of NOx and SO2 from coal boiler flue gases by DC corona discharge ammonia radical shower systems: pilot plant tests
【24h】

Simultaneous removal of NOx and SO2 from coal boiler flue gases by DC corona discharge ammonia radical shower systems: pilot plant tests

机译:通过直流电晕放电氨自由基喷淋系统同时去除燃煤锅炉烟气中的NOx和SO2:中试工厂测试

获取原文
获取原文并翻译 | 示例
       

摘要

Pilot scale tests were conducted for simultaneous removal of NOx and SO2 from coal boiler flue gases by corona discharge induced ammonia radical injection techniques, i.e. the corona radical shower system. Tests were conducted for the flue gas rate from 1000 to 1500 Nm(3)/h, the gas temperature from 62degreesC to 80degreesC, the ammonia-to-total acid gas molecule ratio from 0.88 to 1.3, applied voltage from 0 to 25 kV and NO initial concentration from 53 to 93 ppm. for a fixed SO2 of 800 ppm. The results show that SO2 removal increases with increasing ammonia radical injection rate and non-monotonically depends on in-put electrical power. The NOx removal increases with increasing in-put electrical power and ammonia radical injection rate. Approximately 9 kg Of SO2 were removed by 1 kWh of energy input with 99% Of SO2 removal, while approximately 125 g of NOx was removed by 1 kWh of energy input with 75% of removal efficiency. (C) 2002 Elsevier Science B.V. All rights reserved. [References: 20]
机译:通过电晕放电诱导的氨自由基注入技术(即电晕自由基喷淋系统)进行了中试试验,以同时去除燃煤锅炉烟道气中的NOx和SO2。进行了烟气速率从1000到1500 Nm(3)/ h,气体温度从62摄氏度到80摄氏度,氨与总酸性气体分子比为0.88到1.3,施加电压为0到25 kV和NO初始浓度为53至93 ppm。固定的SO2为800 ppm。结果表明,随着氨自由基注入速率的增加,SO2去除量增加,并且非单调依赖于输入电功率。随着输入电功率和氨自由基注入速率的增加,NOx的去除量也会增加。通过输入1 kWh的能量可去除大约9 kg的SO2,其中SO2去除率为99%,而通过输入1 kWh的能量输入可以去除大约125 g的NOx,去除效率为75%。 (C)2002 Elsevier Science B.V.保留所有权利。 [参考:20]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号