Surface potential measurements after corona charging are reported on metal-insulator structures with artificial defects. On organic anticorrosion coatings, potential cartography shows clear evidence of bad adhesion areas. A detailed analysis has been carried out on printed circuit board composite epoxy fiberglass insulating plates with a calibrated cavity, on which potential decay and return data clearly exhibit a particular response compared with non-voided plates. This response is analyzed in terms of material polarization and charge injection from the interface. We conclude from this analysis that charge injection from the cavity is enhanced, whereas polarization is reduced in the cavity area.
机译:据报道,在具有人工缺陷的金属绝缘体结构上,电晕充电后的表面电势测量结果。在有机防腐涂料上,潜在的制图技术清楚地表明了不良的粘合区域。已对具有校准腔的印刷电路板复合环氧玻璃纤维绝缘板进行了详细分析,与无孔板相比,其上的电位衰减和返回数据显然表现出特定的响应。根据材料极化和从界面注入的电荷来分析此响应。从该分析中我们得出结论,从空腔注入的电荷得到增强,而在空腔区域中的极化减小了。