首页> 外文期刊>Journal of dentistry >Using Little's Irregularity Index in orthodontics: Outdated and inaccurate?
【24h】

Using Little's Irregularity Index in orthodontics: Outdated and inaccurate?

机译:在口腔正畸学中使用Little的不规则指数:过时和不准确?

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: Little's Irregularity Index (LII) was devised to objectively score mandibular incisor alignment for epidemiological studies but has been extended to assess the relative performance of orthodontic brackets, retainer or treatment modalities. Our aim was to examine the repeatability and precision of LII measurements of four independent examiners on the maxillary arch of orthodontic patients. The hypothesis was that the reproducibility of individual contact point displacement measurements, used to calculate the LII score, are inappropriate. Methods: The displacement of the anterior contact points, of the six upper labial segment teeth of the maxillary arch on each of ten casts, were randomly assessed by four examiners at three time-points using LII. Results: Significant correlations were evident between the six examiner-pairs (r > 0.413; p < 0.001) for contact point displacements of >0.5 mm. The coefficients of variation showed that 516 of the 600 individual contact point displacement measurements differed by >20% of the mean. Analyses of variance revealed significant differences (p < 0.047) between examiners for 46% of the contact point displacement measurements. Conclusion: The reproducibility of individual contact point displacement measurements, used to calculate the LII score, is poor such that using LII to assess the performance of orthodontic brackets, retainers or treatment modalities must emphatically be discouraged. Clinical significance: The use of LII by the orthodontic community to predictably determine the outcome of orthodontic treatment modalities in clinical practice cannot be advocated due to the limited accuracy and precision of the technique.
机译:目标:利特尔不规则指数(LII)旨在客观地评估下颌切牙对准度,以进行流行病学研究,但现在已扩展为评估正畸托槽,固定器或治疗方式的相对性能。我们的目的是检查正畸患者上颌弓上四名独立检查员的LII测量的可重复性和准确性。假设是,用于计算LII得分的单个接触点位移测量的可重复性是不合适的。方法:由四名检查者在三个时间点使用LII随机评估上颌弓的六个上唇段上牙的前接触点的位移,十个石膏中的每个。结果:对于接触点位移> 0.5 mm的六个检查者对之间存在明显的相关性(r> 0.413; p <0.001)。变异系数表明,在600个单独的接触点位移测量中,有516个相差均值> 20%。方差分析显示,对于46%的接触点位移测量,检查者之间存在显着差异(p <0.047)。结论:用于计算LII评分的单个接触点位移测量的可重复性很差,因此,必须大力劝阻使用LII评估正畸托槽,固定器或治疗方式的性能。临床意义:由于该技术的准确性和准确性有限,因此不能提倡由正畸社区使用LII来可预测地确定临床实践中正畸治疗方式的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号