首页> 外文期刊>Journal of dentistry >Influence of matrix systems on proximal contact tightness of 2- and 3-surface posterior composite restorations in vivo.
【24h】

Influence of matrix systems on proximal contact tightness of 2- and 3-surface posterior composite restorations in vivo.

机译:基质系统对2面和3面后复合修复体的近端接触紧密度的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: To investigate the influence of cavity preparation (MO/DO/MOD) and type of matrix system on proximal contact tightness of direct posterior composite restorations. MATERIALS AND METHODS: 85 patients in need of a two- or three surface Class II direct composite restoration were randomly divided into two treatment groups. Group 1 was treated with a sectional matrix system combined with a separation ring (Palodent); Group 2 was treated with a circumferential matrix system in combination with a retainer (Tofflemire). Proximal contact tightness was recorded before treatment and directly after finishing the restoration. RESULTS: For the two-surface cavities use of the separation ring resulted in a statistically significantly tighter proximal contacts at both the mesial and distal site (MO: 2.51+/-0.81 N; DO: 2.82+/-1.14 N) compared to the use of the circumferential (MO: -1.08+/-1.04 N; DO: -0.22+/-0.87 N) (p=0.01). Regarding the three-surface (MOD) cavities no statistically significant differences were found between the mesial and distal site, nor was there an effect of the used matrix system. No statistically significant influence of cavity design (mesially/distally) was recorded for all cavities (MO, DO and MOD). CONCLUSIONS: Use of the sectional matrix system in two-surface Class II cavities resulted in statistically significantly tighter proximal contacts than the use of the circumferential matrix system. For the three-surface no statistically significant differences in contact tightness were found between the different matrix systems. Location of the cavity (mesially or distally) did not show to have any statistically significant effect on the obtained proximal contact tightness.
机译:目的:研究腔体准备(MO / DO / MOD)和基质系统类型对直接后路复合修复体近端接触紧密性的影响。材料与方法:将需要两或三个表面II类直接复合修复的85名患者随机分为两个治疗组。第1组用截面矩阵系统结合分离环(Palodent)处理;第2组用周向基质系统结合固定器(Tofflemire)治疗。在治疗前和修复完成后立即记录近端接触紧密度。结果:对于两腔型腔,使用分离环与内侧和外侧部位的近端接触在统计学上明显更紧密(MO:2.51 +/- 0.81 N; DO:2.82 +/- 1.14 N)。使用圆周(MO:-1.08 +/- 1.04 N; DO:-0.22 +/- 0.87 N)(p = 0.01)。关于三表面(MOD)腔,在内侧和远侧部位之间没有发现统计学上的显着差异,也没有使用过的基质系统的影响。没有记录所有腔体(MO,DO和MOD)腔体设计(局部/远侧)的统计显着影响。结论:在两面II类腔中使用截面矩阵系统比使用圆周矩阵系统在统计学上导致近端接触紧密得多。对于三表面,在不同的基质体系之间没有发现接触紧密度的统计学显着差异。腔的位置(近端或远端)对获得的近端接触紧密度没有任何统计学上的显着影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号