首页> 外文期刊>Journal of dentistry >In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses.
【24h】

In vitro vertical misfit evaluation of cast frameworks for cement-retained implant-supported partial prostheses.

机译:对水泥固位的种植体支撑的部分假体的铸造框架进行体外垂直失配评估。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVES: To evaluate the influence of the alloy type and the associated investing and casting techniques, on the marginal adaptation of bridge structures luted onto prefabricated implant abutments. METHODS: Thirty frameworks for three-unit posterior-lower bridges were waxed and cast (10 of cobalt-chromium, 10 of titanium and 10 of palladium-gold). Each structure was cemented onto two prefabricated implant abutments with a special clamp designed to maintain constant seating pressure. The vertical discrepancy around the abutments' margins was assessed by scanning electron microscopy (SEM). One-way ANOVA for independent samples and Scheffe's test were applied to analyze the effect of the alloy type and its recommended investing and casting system on vertical misfit. Student's t-test for independent samples was used to compare misfit values concerning the abutment design (premolar and molar). The significance level was set at alpha=0.05. RESULTS: Cobalt-chromium samples recorded the greatest vertical discrepancies, revealing significant differences with respect to both titanium and palladium-gold structures (p<0.0001). Vertical gaps of the palladium-gold and the titanium casts were not significantly different (p=0.292). Neither statistically significant differences were found between the anterior and posterior abutments' vertical misfit independently from the alloy type and nor within each group of alloys tested (p>0.05). CONCLUSIONS: The vertical fit of the frameworks cast for implant-cemented bridges was influenced by the alloy type and the investing and casting methods. The marginal discrepancy of the three tested alloys could be considered clinically acceptable. A polished technique in the management of titanium could optimize the accuracy of this cast frameworks.
机译:目的:为了评估合金类型以及相关的投资和铸造技术对被预制在种植体基台上的桥结构的边缘适应性的影响。方法:打蜡并铸造30个三单元后下桥的框架(10个钴铬合金,10个钛合金和10个钯金合金)。每个结构通过专用夹具固定在两个预制的种植体基台上,以保持恒定的阀座压力。通过扫描电子显微镜(SEM)评估基台边缘周围的垂直差异。采用单向方差分析(ANOVA)和独立的Scheffe检验分析合金类型及其推荐的浇铸和铸造系统对垂直失配的影响。独立样本的学生t检验用于比较基台设计(前磨牙和磨牙)的失配值。显着性水平设定为α= 0.05。结果:钴铬样品记录了最大的垂直差异,揭示了钛和钯金结构的显着差异(p <0.0001)。钯金和钛铸件的垂直间隙没有显着差异(p = 0.292)。与合金类型无关,在前和后基台的垂直失配之间,在统计学上也没有发现显着差异(p> 0.05)。结论:用于种植体水泥桥的框架的垂直配合受合金类型以及投资和铸造方法的影响。三种被测合金的边际差异在临床上可以认为是可接受的。钛管理中的抛光技术可以优化这种铸造框架的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号