...
首页> 外文期刊>Journal of dentistry >Survival of glass fibre reinforced composite post restorations after 2 years-an observational clinical study.
【24h】

Survival of glass fibre reinforced composite post restorations after 2 years-an observational clinical study.

机译:玻璃纤维增​​强复合材料修复后2年的生存-一项观察性临床研究。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVES: The aim of this study is to provide prospective clinical data for the survival of postendodontic reconstructions of teeth with varying degrees of hard tissue loss using tapered or parallel-sided post shapes. METHODS: Eighty-three patients got 105 glass fibre reinforced posts of tapered (Luscent Anchors, Dentatus, Sweden) and parallel-sided, serrated (FibreKor, Jeneric Pentron, USA) post shape. A dual curing hybrid composite Compolute (3M ESPE, Germany) was used as luting material, EBS-Multi (3M ESPE) as adhesive system and Clearfil Core (Kuraray, Japan) for core built-up. The restorations were followed for a minimum of 24 months. The statistical analysis was performed on a random sub-sample of one restoration per subject. The Fisher exact test was used to compare frequencies of failures after 12 and 24 month. A Kaplan-Meier-analysis was used to analyse time-to-failure in both groups. Differences of survival time between post types were tested with the log-rank test. RESULTS: 3.8% of the restorations failed after 12 month, 12.8% after 24 month, respectively. The main failure type observed was post fractures. All but one failed teeth could be restored. There was no difference in failure frequency between post types after 12 or 24 months. The log-rank test showed no differences in survival between the two types of post (p=0.37). CONCLUSION: Parallel-sided and tapered glass fibre posts result after 2 years of clinical service in an equal rate of survival.
机译:目的:本研究的目的是提供前瞻性的临床数据,以期采用锥形或平行边柱状形状在不同程度的硬组织丢失的情况下进行牙髓牙髓后重建的存活率。方法:83例患者获得了105个玻璃纤维加强的锥形柱(Luscent Anchors,Dentatus,瑞典)和平行的,锯齿状的纤维柱(FibreKor,Jeneric Pentron,美国)。使用双重固化的混合复合复合材料Compolute(德国3M ESPE)作为粘胶材料,使用EBS-Multi(3M ESPE)作为胶粘剂系统,并使用Clearfil Core(日本可乐丽)制造芯材。进行修复至少24个月。对每个受试者一个修复体的随机子样本进行统计分析。 Fisher精确测试用于比较12个月和24个月后的故障频率。使用Kaplan-Meier分析来分析两组的故障时间。用对数秩检验检验员额类型之间的生存时间差异。结果:12个月后修复的失败率为3.8%,24个月后修复的失败率为12.8%。观察到的主要破坏类型是骨折后。除了一颗失败的牙齿,其他所有牙齿都可以恢复。 12或24个月后,不同职位之间的失败频率没有差异。对数秩检验表明,两种类型的职位之间的生存率无差异(p = 0.37)。结论:临床服务2年后,平行玻璃纤维和锥形玻璃纤维桩具有相同的存活率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号