首页> 外文期刊>Journal of dentistry >Clinical performance of metal-free polymer crowns after 3 years in service.
【24h】

Clinical performance of metal-free polymer crowns after 3 years in service.

机译:使用3年后,无金属聚合物牙冠的临床表现。

获取原文
获取原文并翻译 | 示例

摘要

OBJECTIVE: To investigate the influence of location and preparation design on the survival and complication rate of metal-free polymer crowns within a prospective clinical study. METHODS: After randomization, a total of 114 (68 posterior and 46 anterior) single crowns were prepared, either with a chamfer finishing line or with a shoulder combined with occlusal reduction of at least 1mm. Build-ups were made with a composite material, using the corresponding dentin adhesive. After making impressions with polyether material, polymer crowns were manufactured on stone dies and adhesively luted with resin cement. Follow-ups were scheduled after 1 month, 1 year, 2 years and 3 years. Documentation included failures and other complications, as well as ratings of esthetic and functional performance. After 3 years, data from 100 single crowns were statistically evaluated. RESULTS: Within a minimal observation period of 3 years, 10 complications occurred, including 3 total fractures, 3 partial fractures and 3 decementations. Only 4 crowns (3 total fractures +1 partial fracture) had to be replaced, whereas 2 partial fractures could be repaired and all loosened crowns could be recemented. Kaplan-Meier survival analysis did not show any influence of location or preparation design on the complication rate. Esthetic and functional evaluation by the patients revealed a high acceptance of single polymer crowns, indicated by medians of 9-10 on a 10-point-scale. CONCLUSION: Within the 3 year observation period, it can be concluded that 0.5mm chamfer and shoulder preparation ensure that the stability of metal-free polymer crowns for anterior and posterior teeth is acceptable. Long-term stability and wear behavior has still to be evaluated.
机译:目的:探讨前瞻性临床研究中位置和制备设计对无金属聚合物冠的存活率和并发症发生率的影响。方法:随机分组后,共制备114个(68个后方和46个前部)单冠,采用倒角精加工线或肩并结合至少1mm的牙合。使用相应的牙本质粘合剂,用复合材料制成堆积物。用聚醚材料制成印模后,在石模上制造聚合物冠,然后用树脂胶粘剂粘合。计划在1个月,1年,2年和3年后进行随访。文档包括故障和其他并发症,以及美学和功能性能的评定。 3年后,对100个单冠的数据进行统计评估。结果:在最少3年的观察期内,发生了10例并发症,包括3例总骨折,3例局部骨折和3例牙骨质退缩。只需更换4个牙冠(3个总骨折+1个局部骨折),而2个局部骨折可以修复,所有松动的牙冠都可以复位。 Kaplan-Meier生存分析未显示位置或制剂设计对并发症发生率的任何影响。患者的美学和功能评估表明,他们对单个聚合物冠的接受程度很高,以10分制的中位数为9-10表示。结论:在3年的观察期内,可以得出结论:0.5mm的倒角和肩部准备工作确保了无金属聚合物牙冠在前牙和后牙的稳定性是可以接受的。长期稳定性和磨损性能仍有待评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号