首页> 外文期刊>Journal of dentistry >Dentin and enamel bond strengths of dual-cure composite luting agents used with dual-cure dental adhesives.
【24h】

Dentin and enamel bond strengths of dual-cure composite luting agents used with dual-cure dental adhesives.

机译:与双固化牙科胶粘剂一起使用的双固化复合浸润剂的牙本质和牙釉质粘合强度。

获取原文
获取原文并翻译 | 示例
       

摘要

OBJECTIVE: The purpose of this in vitro study was to evaluate and compare dentin and enamel bond strengths obtained with dual-cure composite luting agents when used with dual-cure dental adhesives. METHODS: Human molars were ground flat to expose enamel (n=80) or dentin (n=80). Specimens in each substrate group were randomly assigned to eight treatment sub-groups, according to four adhesive-luting agent combinations and two test conditions (with or without thermocycling). Pre-polymerized composite resin posts (TPH Spectrum) were luted to either the enamel or dentin surfaces with one of the following adhesive-luting agent combinations: (1) Xeno IV Dual Cure (dual-cure self-etch adhesive) and Calibra (dual-cure luting agent); (2) Prime & Bond NT Dual Cure (dual-cure total-etch adhesive) and Calibra; (3) OptiBond All-in-One Dual Cure (dual-cure self-etch adhesive) and Nexus 2 Dual Syringe (dual-cure luting agent); (4) OptiBond Solo Plus Dual Cure (dual-cure total-etch adhesive) and Nexus 2 Dual Syringe. For each treatment sub-group, half the specimens (n=10) were tested after 24h storage in water at 37 degrees C, and the other half (n=10) were tested after thermocycling for 1800 cycles between water baths held at 5 and 55 degrees C, with a dwell time in each bath of 30s, and a transfer time of 10s. Bond strengths were measured in shear mode, and expressed in MPa. The fracture mode (adhesive, cohesive, mixed) was examined. Data were analyzed for statistical significance with a factorial ANOVA and post hoc tests. RESULTS: Mean enamel bond strengths ranged from 8.4MPa for non-thermocycled OptiBond All-in-One|Nexus 2 to 35.5MPa for non-thermocycled Prime & Bond NT|Calibra. Mean dentin bond strengths ranged from 14.5MPa for non-thermocycled OptiBond Solo Plus|Nexus 2 to 30.9MPa for thermocycled Xeno IV|Calibra. The fracture mode was predominantly adhesive for all groups. CONCLUSIONS: On enamel, the total-etch adhesives performed better than their self-etch counterparts, while in dentin, the opposite was found, i.e., the self-etch adhesives performed better than their total-etch counterparts. Thermocycling for 1800 cycles did not affect the SBS of the materials tested to dentin and enamel.
机译:目的:本体外研究的目的是评估和比较双固化复合胶粘剂与双固化牙科胶粘剂一起使用时获得的牙本质和牙釉质的粘结强度。方法:将人类臼齿磨平以暴露牙釉质(n = 80)或牙本质(n = 80)。根据四种胶粘剂稀释剂组合和两种测试条件(有或没有热循环),将每个底物组中的样品随机分为八个处理亚组。使用以下粘合剂-稀释剂组合之一将预聚合的复合树脂桩(TPH Spectrum)涂在牙釉质或牙本质表面:(1)Xeno IV Dual Cure(双固化自蚀刻粘合剂)和Calibra(双固化) -固化剂); (2)Prime&Bond NT Dual Cure(双固化全蚀刻胶)和Calibra; (3)OptiBond多合一双重固化(双重固化自蚀刻粘合剂)和Nexus 2双重注射器(双重固化浸润剂); (4)OptiBond Solo Plus Dual Cure(双固化全蚀刻胶)和Nexus 2 Dual Syringe。对于每个处理子组,一半的样本(n = 10)在37摄氏度的水中储存24小时后进行测试,另一半(n = 10)在5℃和5℃的水浴之间热循环1800次后进行测试。 55摄氏度,在每个浴槽中的停留时间为30秒,传输时间为10秒。粘结强度以剪切模式测量,并以MPa表示。检查了断裂模式(粘合,内聚,混合)。使用阶乘方差分析和事后检验分析数据的统计显着性。结果:搪瓷的平均粘结强度范围从非热循环的OptiBond All-one-Nexus 2的8.4MPa到非热循环的Prime&Bond NT | Calibra的35.5MPa。平均牙本质粘合强度的范围从非热循环的OptiBond Solo Plus | Nexus 2的14.5MPa到热循环的Xeno IV | Calibra的30.9MPa。骨折模式主要是所有组的粘合。结论:在搪瓷上,全蚀刻胶粘剂的性能要优于自蚀刻胶粘剂,而在牙本质中,情况恰恰相反,即自蚀刻胶粘剂的性能要优于全蚀刻胶粘剂。 1800个周期的热循环不会影响牙本质和牙釉质测试材料的SBS。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号