I read with great interest the article by da Silva Pereira and colleagues (1), reporting on an automated technique based on the Griess reaction for the measurement of nitrite in plasma from EDTA-anticoagulated human blood and its use to measure plasma nitrite in healthy overnight fasted volunteers. Also, it is very interesting to read that da Silva Pereira et al. (1) referred to the need of implementing internal quality control (QC) in the analysis of nitrite in human plasma in clinical studies and in clinical chemistry. Although we agree with many points addressed by da Silva Pereira and colleagues, there are many issues which deserve a more careful and critical discussion.
机译:我非常感兴趣地阅读了达席尔瓦·佩雷拉(da Silva Pereira)及其同事的文章(1),该文章报道了一种基于Griess反应的自动技术,用于测量EDTA抗凝人体血液中血浆中的亚硝酸盐及其在健康过夜中的血浆亚硝酸盐测量中的应用。禁食志愿者。同样,读达席尔瓦·佩雷拉(da Silva Pereira)等人的著作也很有趣。 (1)提到在临床研究和临床化学中分析人血浆中亚硝酸盐的过程中需要实施内部质量控制(QC)。尽管我们同意da Silva Pereira及其同事提出的许多观点,但仍有许多问题值得更仔细和严格的讨论。