首页> 外文期刊>Clinical chemistry and laboratory medicine: CCLM >Measurement uncertainty in manual differential leukocyte counting.
【24h】

Measurement uncertainty in manual differential leukocyte counting.

机译:手动差分白细胞计数中的测量不确定度。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: One of the most frequently requested examinations in the clinical laboratory is the differential leukocyte count. Despite many technological improvements, thousands of differential leukocyte counts are made by microscopic examination of a blood smear, counting 100 leukocytes and expressing the fraction of the specific leukocyte types as percentages (rounded to integer values) of the total leukocyte count. Although in the clinical laboratory it is not usual practice to report measurement uncertainties, currently the ISO 15189 standard considers measurement uncertainty as a very helpful element for a comprehensive interpretation of any measurement result. METHODS: The estimation of the measurement uncertainty of each differential leukocyte count result was carried out according to international guidelines. The sources of standard uncertainty taken into account were: pre-metrological variation, random distribution, between-examiner reproducibility, and rounding to an integer. RESULTS: In this example, a sample of blood with a concentration number of leukocytes of 3,5x10(9)/L (1)) is taken into consideration. For each differential leukocyte count result, the standard uncertainties corresponding to each source of measurement uncertainty, as well as the combined and the expanded uncertainties, were estimated with information from the literature. CONCLUSIONS: The procedure presented here to estimate the measurement uncertainty of differential leukocyte count results is appropriate to fulfill the requirements of the ISO 15189 standard related to measurement uncertainty. Knowledge of this uncertainty is helpful in interpreting sequential results obtained in the same patient.
机译:背景:临床实验室中最常要求的检查之一是差异白细胞计数。尽管有许多技术改进,但通过显微镜检查血液涂片,计数100个白细胞并以总白细胞计数的百分比(四舍五入为整数值)来表达特定白细胞类型的分数,可以实现数千种不同的白细胞计数。尽管在临床实验室中通常不报告测量不确定度,但目前ISO 15189标准认为测量不确定度是全面解释任何测量结果的非常有用的元素。方法:根据国际准则对每个差异白细胞计数结果的测量不确定度进行估计。考虑到的标准不确定性的来源是:计量前变化,随机分布,检测者之间的可重复性以及四舍五入为整数。结果:在此示例中,考虑了血液样本中白细胞浓度为3,5x10(9)/ L(1))。对于每个差异性白细胞计数结果,利用来自文献的信息来估算与每种测量不确定性来源相对应的标准不确定性,以及组合不确定性和扩展不确定性。结论:这里介绍的估计差异白细胞计数结果的测量不确定度的程序适合满足ISO 15189标准关于测量不确定度的要求。了解这种不确定性有助于解释同一患者获得的顺序结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号