首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Determination of fluorescent whitening agents in laundry detergents and surface waters by solid-phase extraction and ion-pair high-performance liquid chromatography
【24h】

Determination of fluorescent whitening agents in laundry detergents and surface waters by solid-phase extraction and ion-pair high-performance liquid chromatography

机译:固相萃取-离子对高效液相色谱法测定衣物洗涤剂和地表水中的荧光增白剂

获取原文
获取原文并翻译 | 示例
           

摘要

A simple method was developed to detect four stilbene-type disulfonate and one distyrylbiphenyl-type fluorescent whitening agents (FWAs) in household laundry detergents and surface waters by ion-pair high-performance liquid chromatography. The FWA concentrations in detergents were measured directly. The contents of FWAs in water samples were extracted by solid-phase extraction (C-18-SPE) with ion-pairing reagent, and were then determined by an isocratic ion-pair chromatography (IPC) using a C-18 column, applying tetrabutylammonium hydrogensulfate (TBA) as the ion-pairing reagent in mobile phase, and equipped with fluorescence detection. Water samples at various pH conditions for SPE were evaluated. Experimental results indicate that the proposed method is precise and sensitive in analyzing FWAs, and enables quantitation of 0.01 -0.1 mu g/l in 100 ml water samples. The recovery rates of FWAs in spiked water samples were between 73 and 89%, and the precision (RSD) ranged from 2.6 to 8.9%. Over 7200 mu g/g of 4,4'-bis(2-sulfostryl)-biphenyl (DSBP) and 2320 mu g/g of 4,4-bis[(4-amino-6-morpholino-1,3,5-triazine-2-yl)-amino]stilbene-2,2'-disulfonate (DAS1) were detected in household laundry detergents. Trace amounts of DSBP were detected in surface water samples ranging from 0.2 to 3.7 mu g/l. (c) 2005 Elsevier B.V. All rights reserved.
机译:开发了一种简单的方法,通过离子对高效液相色谱法检测家用洗衣粉和地表水中的四苯乙烯型二磺酸盐和二苯乙烯基联苯型荧光增白剂(FWA)。直接测量清洁剂中的FWA浓度。使用离子对试剂通过固相萃取(C-18-SPE)萃取水样品中FWA的含量,然后使用C-18柱通过等度离子对色谱法(IPC)使用四丁基铵进行测定流动相中的离子对试剂硫酸氢盐(TBA),并具有荧光检测功能。评估了在各种pH条件下用于SPE的水样品。实验结果表明,该方法对FWAs的分析是准确而灵敏的,并且能够定量100 ml水样品中的0.01 -0.1μg / l。加标水样中FWA的回收率在73%至89%之间,精密度(RSD)为2.6%至8.9%。超过7200微克/克的4,4'-双(2-磺酰基)-联苯(DSBP)和2320微克/克的4,4-双[(4-氨基-6-吗啉代-1,3,5在家用洗衣粉中检测到-三嗪-2-基)-氨基]苯乙烯-2,2'-二磺酸盐(DAS1)。在地表水样品中检测到痕量的DSBP,范围为0.2至3.7μg / l。 (c)2005 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号