首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Analysis of class 1 residual solvents in pharmaceuticals using headspace-programmed temperature vaporization-fast gas chromatography-mass spectrometry
【24h】

Analysis of class 1 residual solvents in pharmaceuticals using headspace-programmed temperature vaporization-fast gas chromatography-mass spectrometry

机译:顶空程序升温汽化-快速气相色谱-质谱法分析药物中的1类残留溶剂

获取原文
获取原文并翻译 | 示例
           

摘要

A sensitive method is presented for the fast screening and determination of residual class 1 solvents (1,1-dichloroethene, 1,2-dichloroethane, 1,1,1-trichloroethane, carbon tetrachloride and benzene) in pharmaceutical products. The applicability of a headspace (HS) autosampler in combination with GC equipped with a programmed temperature vaporizer (PTV) and a MS detector is explored. Different injection techniques were compared. The benefits of using solvent vent injection instead of split or splitless-hot injection for the measurement of volatile compounds are shown: better peak shapes, better signal-to-noise ratios, and hence better detection limits. The proposed method is extremely sensitive. The limits of detection ranged from 4.9 ppt (benzene) to 7.9 ppt (1,2-dichloroethane) and precision (measured as the relative standard deviation) was equal to or lower than 12% in all cases. The method was applied to the determination of residual solvents in nine different pharmaceutical products. The analytical performance of the method shows that it is appropriate for the determination of residual class 1 solvents and has much lower detection limits than the concentration limits proposed by the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV. (c) 2006 Elsevier B.V. All rights reserved.
机译:提出了一种灵敏的方法,用于快速筛选和测定药品中的残留1类溶剂(1,1-二氯乙烯,1,2-二氯乙烷,1,1,1-三氯乙烷,四氯化碳和苯)。探索了顶空(HS)自动进样器与配备有程序温度蒸发器(PTV)和MS检测器的GC的结合使用。比较了不同的注射技术。显示了使用溶剂排气注入代替分流或不分流热注入来测量挥发性化合物的好处:更好的峰形,更好的信噪比和更好的检测限。所提出的方法非常敏感。检出限范围为4.9 ppt(苯)至7.9 ppt(1,2-二氯乙烷),精密度(以相对标准偏差衡量)在所有情况下均等于或低于12%。该方法用于测定九种不同药品中的残留溶剂。该方法的分析性能表明,该方法适用于测定残留的1类溶剂,其检出限比国际人用药品注册技术要求国际协调会议(ICH)提出的浓度限低得多。 。由于使用了PTV,因此与传统的顶空方法相比,所提出的方法在灵敏度上有了明显的提高。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号