A new experimental device for high-performance capillary electrophoresis (HPCE) with a double UV detection system and with thermostating of the whole separation compartment was developed. UV detection is doubled by producing two apertures placed symmetrically close to the axis of the optical path of the single-beam UV detector and by the adjustment of the capillary loop on these two apertures. The double-detection system allows exact measurements of electrophoretic and electroosmotic flow velocities. A procedure for the determination of effective mobilities from the data obtained by the double UV detection system was developed and applied to determine the effective mobilities of synthetic peptides (diglycine, triglycine, growth hormone releasing peptide and its derivatives and fragments). The measurements are performed at constant temperature (25 degrees C) and low input power at which temperature increase in the capillary can be neglected and temperature corrections of temperature-dependent magnitudes need not be included in the calculations. [References: 17]
机译:开发了一种新型的用于高性能毛细管电泳(HPCE)的实验设备,该设备具有双重UV检测系统和整个分离室的恒温功能。通过产生两个对称于单光束紫外线检测器光路轴附近的孔径,并通过调节这两个孔径上的毛细环,可使紫外线检测倍增。双重检测系统可以精确测量电泳和电渗流速。开发了一种通过双紫外检测系统获得的数据确定有效迁移率的方法,并将其应用于确定合成肽(二甘氨酸,三甘氨酸,生长激素释放肽及其衍生物和片段)的有效迁移率。测量是在恒定温度(25摄氏度)和低输入功率下执行的,在该功率下可以忽略毛细管中的温度升高,并且计算中不必包括温度相关幅度的温度校正。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号