首页> 外文期刊>Journal of computer assisted tomography >Dual-energy index value of luminal air in fecal-tagging computed tomography colonography: Findings and impact on electronic cleansing
【24h】

Dual-energy index value of luminal air in fecal-tagging computed tomography colonography: Findings and impact on electronic cleansing

机译:粪便标记计算机断层摄影结肠造影中腔内空气的双能指数值:发现及其对电子清洗的影响

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The purpose of our study was to measure the dual-energy index (DEI) value of colonic luminal air in both phantom and clinical fecal-tagging dual-energy computed tomography (CT) colonography (DE-CTC) images and to demonstrate its impact on dual-energy electronic cleansing. METHODS: For the phantom study, a custom-ordered colon phantom was scanned by a dual-energy CT scanner (SOMATON Definition Flash; Siemens Healthcare, Forchheim, Germany) at two photon energies: 80 and 140 kVp. Before imaging, the phantom was filled with a 300-mL mixture of simulated fecal materials tagged by a nonionic iodinated contrast agent at three contrast concentrations: 20, 40, and 60 mg/mL. Ten regions-of-interest (ROIs) were randomly placed in each of the colonic luminal air, abdominal fat, bony structure, and tagged material in each scan. For the clinical study, 22 DE-CTC (80 and 140 kVp) patient cases were collected, who underwent a low-fiber, low-residue diet bowel preparation and orally administered iodine-based fecal tagging. Twenty ROIs were randomly placed in each of the colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material in each scan. For each ROI, the mean CT values in both 80- and 140-kVp images were measured, and then its DEI was calculated. RESULTS: In the phantom study, the mean DEI values of luminal air were 0.270, 0.298, 0.386, and 0.402 for the four groups of tagging conditions: no tagged material and tagged with three groups of contrast concentrations at 20, 40, and 60 mg/mL. In the clinical study, the mean DEI values were 0.341, -0.012, -0.002, and 0.188 for colonic luminal air, abdominal fat, abdominal soft tissue, and tagged fecal material, respectively. CONCLUSIONS: In our study, we observed that the DEI values of colonic luminal air in DE-CTC images (>0.10) were substantially higher than the theoretical value of 0.0063. In addition, the observed DEI values of colonic luminal air were significantly higher than those of soft tissue. These findings have an important impact on electronic cleansing: it may provide an effective means of differentiating colonic soft-tissue structures from the air-tagging mixture caused by the partial volume effect and thus of minimizing the cleansing artifacts.
机译:目的:我们的研究目的是在幻影和粪便标记双能计算机断层扫描(CT)结肠摄影(DE-CTC)图像中测量结肠腔内空气的双能指数(DEI)值,并证明其对双能电子清洗的影响。方法:对于体模研究,使用双能CT扫描仪(SOMATON Definition Flash;西门子医疗公司,福希海姆,德国)以两种光子能量80和140 kVp扫描定制的结肠体模。成像之前,模型中装满了300 mL模拟粪便混合物,该混合物由非离子碘化造影剂标记,具有三种造影剂浓度:20、40和60 mg / mL。在每次扫描中,将十个感兴趣区域(ROI)随机放置在每个结肠腔内空气,腹部脂肪,骨结构和标记材料中。在临床研究中,收集了22例DE-CTC(80 kVp和140 kVp)患者病例,他们接受了低纤维,低残留饮食肠准备并口服了碘基粪便标签。在每次扫描中,将20个ROI随机放置在结肠腔内空气,腹部脂肪,腹部软组织和带标签的粪便中。对于每个ROI,均测量了80kV和140kVp图像中的平均CT值,然后计算了其DEI。结果:在幻像研究中,四组标签条件的腔内空气的平均DEI值分别为0.270、0.298、0.386和0.402:无标签材料,并在20、40和60 mg时用三组对比浓度标签/毫升在临床研究中,结肠腔内空气,腹部脂肪,腹部软组织和带标签的粪便材料的平均DEI值分别为0.341,-0.012,-0.002和0.188。结论:在我们的研究中,我们观察到DE-CTC图像中结肠腔空气的DEI值(> 0.10)大大高于理论值0.0063。此外,观察到的结肠腔内空气的DEI值明显高于软组织的DEI值。这些发现对电子清洁产生了重要影响:它可以提供一种有效的手段,将结肠​​软组织结构与部分容积效应引起的空气标记混合物区分开,从而最大程度地减少清洁伪影。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号