Preloaded injector for intraocular lens implantation without the use of ophthalmic viscosurgical devices.

机译:预装注射器,用于不使用眼科内窥镜手术设备的人工晶状体植入。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To evaluate a new preloaded intraocular lens (IOL) injector (KS-VF) that uses ordinary irrigating solution alone to implant a foldable IOL and form and maintain the anterior chamber and capsular bag formation and maintenance. SETTING: Department of Ophthalmology, Kitasato University, School of Medicine, Kanagawa, Japan. METHODS: The KS-VF disposable injector is preloaded with a 3-piece silicone IOL, which is ejected after the injector is filled with ordinary irrigating solution via an irrigation/aspiration tube connected to the injector body.The space created by the irrigating solution in the anterior chamber and the capsular bag was compared with that created by conventional preloaded injectors filled with an ophthalmic viscosurgical device in a post-phacoemulsification porcine eye. Intraocular lens ejection speed and resistance with the KS-VF injector and with the conventional preloaded injectors were also measured and compared. In addition, intraocular pressure was measured in the porcine eye and in 11 eyes of 11 patients. RESULTS: In vitro examination revealed no significant difference in the IOL ejection mechanism between the KS-VF and conventional preloaded injectors. The use of irrigating solution was not inferior to that of OVD and provided sufficient space in the anterior chamber and capsular bag. In clinical use, IOLs were successfully implanted without incident into the capsular bag formed with the irrigating solution. CONCLUSIONS: The KS-VF implants a foldable IOL with irrigating solution alone and requires no intraocular injection or removal of OVD. Possible advantages include improvements in surgical efficiency, avoidance of postoperative IOP rise from residual OVD, and reduced surgical cost.
机译:目的:评估一种新的预加载人工晶状体(IOL)注射器(KS-VF),该注射器单独使用普通冲洗液植入可折叠的IOL,并形成并维持前房和囊袋的形成和维护。地点:日本北里大学医学院眼科。方法:KS-VF一次性进样器预装了3件式有机硅IOL,在通过连接到进样器主体的冲洗/抽吸管将普通的冲洗液充满进样器后将其弹出。将前房和囊袋与在超声乳化后猪眼中装有眼内窥镜外科手术设备的传统预装注射器产生的前腔和囊袋进行了比较。还测量并比较了KS-VF注射器和常规预加载注射器的人工晶状体顶出速度和阻力。另外,在11只患者的猪眼和11只眼中测量眼内压。结果:体外检查显示,KS-VF和传统的预装注射器之间的IOL弹出机制没有显着差异。冲洗液的使用并不比OVD差,并且在前房和囊袋中提供了足够的空间。在临床使用中,IOL已成功植入,没有入射到由冲洗液形成的囊袋中。结论:KS-VF植入可折叠IOL并单独使用冲洗液,不需要眼内注射或去除OVD。可能的优势包括提高手术效率,避免因残留OVD引起的术后IOP升高以及降低手术成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号