PURPOSE: To assess the repeatability of corneal wavefront aberrations derived from Pentacam (Oculus) corneal topography. SETTING: Flinders Eye Centre, Flinders Medical Centre, Bedford Park, South Australia, Australia. METHODS: Forty-five normal participants and 10 participants with keratoconus were tested. Intraobserver and interobserver repeatability was determined using 4 observers within and between sessions. Topographical maps were exported to external software, and corneal first-surface wavefront aberrations were calculated using a 10th-order Zernike expansion over a 6.0 mm optical zone. Repeatability was determined with Bland-Altman limits of agreement and expressed as the coefficient of repeatability (COR). RESULTS: Initial data showed high wavefront aberrations in normal participants and poor repeatability. Topographical maps showed extrapolated topography in zones without data acquisition; maps with less than 6.0 mm of complete data were excluded in the final analysis. The mean wavefront aberrations for normal participants remained high, but repeatability improved. The COR relative to the magnitude of wavefront aberrations was high (average 100%) across all modal pairs and orders, although best for total higher-order root mean square. Participants with keratoconus had higher magnitude wavefront aberrations and poorer repeatability but similar COR to average wavefront aberration ratios. Examination of raw elevation data showed poor repeatability. CONCLUSIONS: Wavefront aberrations calculated from Pentacam corneal topography were large in magnitude, and reliability was poor, largely due to variability in corneal elevation data. Intraobserver and interobserver reliability within and between sessions was comparable. The Pentacam was not reliable in measuring corneal wavefront aberrations.
机译:目的:评估源自Pentacam(Oculus)角膜地形图的角膜波前像差的可重复性。地点:澳大利亚南澳大利亚贝德福德公园弗林德斯医疗中心弗林德斯眼科中心。方法:对45名正常参与者和10名圆锥角膜参与者进行了测试。观察者内部和观察者之间的可重复性是使用会话内和会话之间的4位观察者确定的。将地形图导出到外部软件,并使用6.0毫米光学区域上的10阶Zernike展开来计算角膜第一表面波前像差。重复性是通过Bland-Altman一致性极限确定的,并表示为重复性系数(COR)。结果:初始数据显示正常参与者的波前像差高,可重复性差。地形图显示没有数据采集的区域中的外推地形;最终分析中排除了完整数据少于6.0毫米的地图。正常参与者的平均波前像差仍然很高,但重复性得到了改善。在所有模态对和阶中,相对于波前像差大小的COR都很高(平均100%),尽管最适合总的高阶均方根。圆锥角膜参与者的波前像差幅度较大,重复性较差,但COR与平均波前像差比率相似。原始高程数据的检查显示可重复性很差。结论:从Pentacam角膜地形图计算出的波前像差幅度大,可靠性差,这主要是由于角膜仰角数据的可变性。会话内部和会话之间的观察员内部和观察员之间的可靠性是可比的。 Pentacam在测量角膜波前像差方面不可靠。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号