Correlations between corneal and total wavefront aberrations

机译:角膜和总波前像差之间的相关性

获取原文
获取原文并翻译 | 示例

摘要

Purpose: Corneal topography data expressed as corneal aberrations are frequently used to report corneal laser surgery results. However, the optical image quality at the retina depends on all optical elements of the eye such as the human lens. Thus, the aim of this study was to investigate the correlations between the corneal and total wavefront aberrations and to discuss the importance of corneal aberrations for representing corneal laser surgery results. Methods: Thirty three eyes of 22 myopic subjects were measured with a corneal topography system and a Tschernig-type wavefront analyzer after the pupils were dilated to at least 6 mm in diameter. All measurements were centered with respect to the line of sight. Corneal and total wavefront aberrations were calculated up to the 6th Zernike order in the same reference plane. Results: Statistically significant correlations (p < 0.05) between the corneal and total wavefront aberrations were found for the astigmatism (C3,C5) and all 3rd Zernike order coefficients such as coma (C7,C8). No statistically significant correlations were found for all 4th to 6th order Zernike coefficients except for the 5th order horizontal coma C18 (p = 0.003). On average, all Zernike coefficients for the corneal aberrations were found to be larger compared to Zernike coefficients for the total wavefront aberrations. Conclusions: Corneal aberrations are only of limited use for representing the optical quality of the human eye after corneal laser surgery. This is due to the lack of correlation between corneal and total wavefront aberrations in most of the higher order aberrations. Besides this, the data present in this study yield towards an aberration balancing between corneal aberrations and the optical elements within the eye that reduces the aberration from the cornea by a certain degree. Consequently, ideal customized ablations have to take both, corneal and total wavefront aberrations, into consideration.
机译:目的:表示为角膜畸变的角膜地形图数据经常用于报告角膜激光手术结果。但是,视网膜上的光学图像质量取决于眼睛的所有光学元素,例如人的晶状体。因此,本研究的目的是研究角膜像差与总波前像差之间的相关性,并讨论角膜像差对代表角膜激光手术结果的重要性。方法:将瞳孔扩大到至少6 mm的直径后,使用角膜地形图系统和Tschernig型波前分析仪对22位近视受试者的33只眼睛进行了测量。所有测量均相对于视线居中。在同一参考平面上,计算出直至Zernike六阶的角膜和总波前像差。结果:发现散光(C3,C5)和所有第三个Zernike阶数系数(例如昏迷)(C7,C8)在角膜和总波前像差之间具有统计学上的显着相关性(p <0.05)。除5级水平昏迷C18外(p = 0.003),所有4至6级Zernike系数均无统计学意义的相关性。平均而言,发现与所有波前像差的Zernike系数相比,所有角膜像差的Zernike系数都更大。结论:角膜像差仅用于代表角膜激光手术后人眼的光学质量。这是由于在大多数高阶像差中角膜和总波前像差之间缺乏相关性。除此之外,本研究中的数据还有助于实现角膜像差与眼睛内光学元件之间的像差平衡,从而在一定程度上降低了角膜的像差。因此,理想的定制消融必须同时考虑角膜和总波前像差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号