首页> 外文期刊>Journal of cataract and refractive surgery >Comparative micromorphologic in vitro porcine study of IntraLase and Femto LDV femtosecond lasers.
【24h】

Comparative micromorphologic in vitro porcine study of IntraLase and Femto LDV femtosecond lasers.

机译:IntraLase和Femto LDV飞秒激光的体外微观形态比较猪研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To assess flap creation and stromal bed quality of 2 femtosecond refractive surgery lasers in laser in situ keratomileusis. SETTING: Augenklinik am Neumarkt, Cologne, Germany. METHODS: Corneal flaps were created in 115 freshly enucleated porcine eyes using the 60 kHz IntraLase FS laser (Advanced Medical Optics) and a prototype model of the Femto LDV femtosecond laser (Ziemer Ophthalmic Systems AG). The parameters that were evaluated included actual versus intended thickness by subtraction pachymetry, cutting and total suction time, quality of flap edges, and smoothness of flap beds. Confocal microscopy (Atos PLmu [Altos GmbH]) was used to objectively determine the root mean square (RMS) of the surface roughness of the stromal bed. RESULTS: Cutting time was 31 seconds for the 60 kHz IntraLase FS laser and 38 seconds for the Femto LDV laser. With both lasers, the standard deviation in achieved versus intended flap thickness was small (136 microm +/- 10 and 130 +/- 9 microm, respectively). Under micromorphologic examination, stromal bed quality was slightly better with the IntraLase. The RMS of bed roughness was 1.6 +/- 0.5 microm with the IntraLase and 2.0 +/- 0.4 microm with the Femto LDV. Neither laser showed significant thermal or mechanical damage in adjacent tissue layers of the stromal bed. The laser-induced bubble layer was more pronounced with the IntraLase. CONCLUSION: The laser cuts of the IntraLase FS and Femto LDV femtosecond lasers were equally smooth and of excellent quality. The standard deviation of the flap thickness was small and equal in both systems.
机译:目的:评估在原位角膜磨镶术中使用2枚飞秒屈光手术激光的皮瓣产生和基质床质量。地点:德国科隆Neumarkt的Augenklinik。方法:使用60 kHz IntraLase FS激光(Advanced Medical Optics)和Femto LDV飞秒激光(Ziemer Ophthalmic Systems AG)的原型模型,在115只刚摘除眼镜的猪眼中制作角膜瓣。所评估的参数包括通过减量测厚法测得的实际厚度与预期厚度,切割和总抽吸时间,襟翼边缘的质量以及襟翼床的光滑度。共聚焦显微镜(Atos PLmu [Altos GmbH])用于客观确定基质床表面粗糙度的均方根(RMS)。结果:60 kHz IntraLase FS激光器的切割时间为31秒,而Femto LDV激光器的切割时间为38秒。对于这两种激光器,所获得的相对于预期的瓣厚度的标准偏差都很小(分别为136微米+/- 10和130 +/- 9微米)。在显微形态学检查下,IntraLase的基质床质量稍好。 IntraLase的床粗糙度RMS为1.6 +/- 0.5微米,Femto LDV的床粗糙度为2.0 +/- 0.4微米。激光在基质床的相邻组织层中均未显示出明显的热损伤或机械损伤。激光诱导的气泡层在IntraLase中更加明显。结论:IntraLase FS和Femto LDV飞秒激光器的激光切割同样光滑且质量优良。襟翼厚度的标准偏差在两个系统中均较小且相等。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号