首页> 外文期刊>Journal of cataract and refractive surgery >Clinical presentation of intraocular lens schisis.
【24h】

Clinical presentation of intraocular lens schisis.

机译:眼内晶状体裂变的临床表现。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To analyze the clinical presentation and implications of cavity or schisis formation in the MemoryLens (CIBA Vision) intraocular lens (IOL) optic. SETTING: Eye Department, Red Cross Hospital, Munich, Germany. METHODS: This study was a retrospective chart review and slitlamp photography analysis of IOL schisis. RESULTS: Four patients with IOL schisis were identified and their charts analyzed. Clinically, the schisis presented as a sharply demarcated round structure. The aspect was clear on coaxial illumination, but on tangential illumination the schisis area was opaque. Patients experienced glare, foggy vision, and deteriorated visual function or had no symptoms. One patient lost visual acuity, and the IOL was explanted. CONCLUSIONS: Clinically, IOL schisis was easily differentiated from cases of IOL opacification due to calcification. The clinical implication was not uniform, ranging from no symptoms to great visual disturbance leading to explantation of the IOL. The cause of this complicationremains unclear. A possible explanation is the impact of solvent-induced tensile stress on the IOL optic material during the manufacturing process.
机译:目的:分析MemoryLens(CIBA Vision)人工晶状体(IOL)光学器件中腔或裂隙形成的临床表现和意义。地点:德国慕尼黑红十字会医院眼科。方法:本研究是回顾性图表回顾和裂隙灯摄影分析的人工晶体分裂症。结果:确定了4例IOL分裂症患者并对其图表进行了分析。临床上,裂隙表现为清晰划定的圆形结构。在同轴照明下,外观清晰,但是在切向照明下,裂隙区是不透明的。患者出现眩光,视力模糊,视觉功能恶化或没有症状。一名患者失去了视力,并移出了人工晶体。结论:在临床上,由于钙化,人工晶体分裂容易与人工晶状体混浊病例区分开。临床意义不统一,从无症状到导致IOL移出的严重视觉障碍。这种并发症的原因仍不清楚。一个可能的解释是在制造过程中溶剂引起的拉伸应力对IOL光学材料的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号