...
首页> 外文期刊>Journal of cataract and refractive surgery >Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes.
【24h】

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes.

机译:在近视有晶状体眼中植入可折叠虹膜-爪状晶状体后,高阶像差的变化。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. SETTING: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. METHODS: This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 months after pIOL implantation. RESULTS: The mean preoperative sphere was -8.12 diopters (D) +/- 2.01 (SD) (range -12.25 to -3.75 D) and the mean preoperative cylinder, -0.90 +/- 0.62 D (range -2.50 to 0.00 D). The Z3(1) and Z(3)(-1) coefficients decreased after implantation of the foldable iris-claw pIOL, but the decrease was not statistically significant (P = .078 and P = .45, respectively). There was a statistically significant reduction in Z4(0) in the first postoperative week (P = .038), but the decrease was not significant thereafter. There was a statistically significant reduction in total RMS wavefront error from preoperatively to all values postoperatively (P = .008). CONCLUSION: Over a 12-month follow-up, 3rd-order and 4th-order HOAs did not increase after foldable iris-claw pIOL implantation in myopic eyes.
机译:目的:评估近视眼植入可折叠虹膜-爪状晶状体人工晶状体(pIOL)后高阶像差(HOA)的变化。地点:德国美因茨约翰内斯·古腾堡大学眼科。方法:该前瞻性非随机对照自我对照试验包括41眼在2003年7月至2004年11月之间植入可折叠虹膜爪pIOL的眼睛。术前使用相同瞳孔大小测量和计算所有患者HOA数据(Zernike系数)。术后,计算出均方根(RMS)波前误差。术前以及pIOL植入后1周,3、6和12个月进行检查。结果:术前平均球面度为-8.12屈光度(D)+/- 2.01(SD)(范围-12.25至-3.75 D)和术前平均柱面度为-0.90 +/- 0.62 D(范围-2.50至0.00 D) 。 Z3(1)和Z(3)(-1)系数在可折叠虹膜爪pIOL植入后下降,但下降没有统计学意义(分别为P = .078和P = .45)。术后第一周Z4(0)的降低具有统计学意义(P = .038),但此后的降低并不显着。从术前到术后所有值的总RMS波前误差均有统计学意义的降低(P = .008)。结论:在12个月的随访中,可折叠虹膜爪pIOL植入近视眼后,三阶和四阶HOA没有增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号