Clinical application of 11-deoxycortisol in visualizing prolapsed vitreous body after posterior capsule rupture in cataract surgery.

机译:11-脱氧皮质醇在白内障手术后囊破裂后可视化玻璃体脱垂的临床应用。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To compare the temperature profiles of 3 popular phacoemulsification units (Alcon AdvanTec Legacy, Bausch & Lomb Millennium, and AMO Sovereign WhiteStar) under similar operating conditions in air. SETTING: Jules Stein Eye Institute and the Department of Ophthalmology, David Geffen School of Medicine at University of California Los Angeles, Los Angeles, California, USA. METHODS: Phacoemulsification probes from the 3 units were placed side-by-side in air and imaged in the infrared using an FLIR model P60 ThermaCAM. The highest temperature produced by each probe was measured 10 and 30 seconds after power application. Testing was performed under conditions that might produce a corneal burn. Irrigation flow was set at 1 cc/min to simulate a tight incision. Aspiration flow was set at 0 cc/min to simulate occlusion. Wound compression was simulated by suspending 22.6-gram weights from the silicone sleeves. The Alcon AdvanTec Legacy and Bausch & Lomb Millennium were operated in pulse mode at 15 Hertz; 50% duty cycle; and 10%, 30% and 50% power. The AMO Sovereign WhiteStar was operated in both C/F (56 Hz, 33% duty cycle) and C/L (33 Hz, 20% duty cycle) modes. RESULTS: The Millennium and the Sovereign generated higher temperatures than the Legacy with almost all experimental conditions (at 10%, 30%, and 50% powers; with and without sleeve compression; with manufacturers' and identical irrigating sleeves; and in continuous and pulse modes). CONCLUSIONS: The Bausch & Lomb Millennium and the AMO Sovereign WhiteStar, operating in both pulse and continuous modes, generated higher peak temperatures than the Alcon AdvanTec Legacy with very controlled operating conditions in air and with a variety of power, load, and duty-cycle settings.
机译:目的:比较三种在空气中相似操作条件下常用的超声乳化装置(Alcon AdvanTec Legacy,博士伦(Bausch&Lomb Millennium)和AMO主权白星)的温度曲线。地点:美国加利福尼亚大学洛杉矶分校大卫·格芬医学院朱尔斯·斯坦眼科研究所和眼科。方法:将3个单元的超声乳化探头并排放置在空气中,并使用FLIR P60型ThermaCAM在红外下成像。通电后10秒和30秒测量每个探针产生的最高温度。在可能产生角膜烧伤的条件下进行测试。将灌溉流量设置为1 cc / min,以模拟紧密切口。抽吸流量设置为0 cc / min,以模拟阻塞。通过从硅胶套上悬挂22.6克砝码来模拟伤口压缩。 Alcon AdvanTec Legacy和Bausch&Lomb Millennium以15赫兹的脉冲模式运行; 50%占空比;以及10%,30%和50%的功率。 AMO Sovereign WhiteStar在C / F(56 Hz,33%占空比)和C / L(33 Hz,20%占空比)模式下运行。结果:在几乎所有实验条件下(10%,30%和50%的功率;带有或不带有袖子压缩;使用制造商的和相同的灌溉袖子;连续和脉动的情况下,千禧年和君主产生的温度都比传统遗产高。模式)。结论:以脉冲和连续模式运行的博士伦和AMO Sovereign WhiteStar产生的峰值温度比Alcon AdvanTec Legacy高,在空气中的运行条件受到严格控制,并且具有多种功率,负载和占空比设置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号