...
首页> 外文期刊>Journal of cataract and refractive surgery >Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge.
【24h】

Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge.

机译:在兔眼后囊混浊中植入具有增强的方形边缘的亲水性丙烯酸人工晶状体。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate the development of posterior capsule opacification (PCO) after implantation of single-piece hydrophilic acrylic intraocular lenses (IOLs) with an enhanced square edge. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The standard 570H Centerflex (Rayner Ltd.) design was compared to 2 new designs with enhanced square edges: the 570E and the 570C. Ten IOLs of each type were implanted in a randomized manner by the same surgeon in 15 pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and the eyes were analyzed from the posterior view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was graded from 0 to 4. The area of Soemmering's ring was graded from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL edge and IOL centration and fixation. Results from the posterior view were complemented by histopathological evaluation. RESULTS: Posterior capsule opacification was lowest in the 570C group, highest in the 570H group, and intermediate in the 570E group. There was a statistically significant difference between the 3 groups in peripheral PCO (P = .039). No significant difference was found between the groups in the other parameters analyzed. When cell ingrowth occurred with the 570H, it started at the optic-haptic junctions, as observed during the clinical follow-up and confirmed by gross and histopathological analyses. CONCLUSIONS: The square optic edge is the most important IOL design feature for PCO prevention. However, it should be present for 360 degrees around the IOL optic to provide an effective barrier effect.
机译:目的:评估植入具有增强的方形边缘的单片亲水性丙烯酸人工晶状体(IOL)后,后囊混浊(PCO)的发展。地点:美国犹他州盐湖城犹他大学John A. Moran眼科中心。方法:将标准570H Centerflex(Rayner Ltd.)设计与2种具有增强的方形边缘的新设计进行了比较:570E和570C。同一位外科医生以随机方式将每种类型的10个IOL植入15只有色兔子中。随访3周后,处死兔子并从后方观察眼睛。中心PCO,外围PCO和Soemmering环形成的强度从0到4级。Soemmering环的面积根据所涉及的象限数从0到4级。分析的其他参数是撕囊对人工晶状体边缘的覆盖率以及人工晶状体的定中心和固定。后视图的结果得到了组织病理学评估的补充。结果:后囊混浊在570C组中最低,在570H组中最高,在570E组中度。外周PCO的3组之间存在统计学上的显着差异(P = .039)。在所分析的其他参数中,各组之间没有发现显着差异。当570H发生细胞向内生长时,正如在临床随访期间观察到的那样,它从视觉-触觉连接处开始,并通过总体和组织病理学分析证实。结论:方形光学边缘是预防PCO的最重要的IOL设计功能。但是,它应该在IOL光学器件周围360度存在,以提供有效的屏障效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号