PURPOSE: To evaluate the outcome of posterior capsule opacification (PCO) after implantation in rabbit eyes of currently available 3-piece and 1-piece hydrophobic acrylic intraocular lenses (IOLs) with square optic edges. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The 3-piece designs evaluated were the AR40e (Advanced Medical Optics Inc.) and the MA60AC (Alcon, Inc.); the 1-piece designs were the SA60AT and the SA30AT (Alcon, Inc.). Nine lenses of each type were implanted in a randomized manner by the same surgeon in 18 Dutch Belted pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and analyses of the enucleated eyes were performed from the posterior or Miyake-Apple view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was scored from 0 to 4. The area of Soemmering's ring formation was also scored from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL anterior surface, IOL centration, fixation, and presence of striae. Results from the posterior view were complemented by histopathologic evaluation of the eyes. RESULTS: No statistically significant difference was found between the 4 groups of IOLs in the parameters analyzed from the posterior view. When cell ingrowth occurred with the 1-piece designs, causing peripheral and central PCO formation, it was more likely to start at the optic-haptic junctions, as observed during the clinical follow-up with slitlamp examination and confirmed by gross and histopathologic analyses of the enucleated eyes. CONCLUSIONS: The square, truncated optic edge is the most important IOL design feature for PCO prevention. The optic-haptic junctions of the 1-piece designs appear to be sites where the barrier effect of the truncated optic edge is less effective.
机译:目的:评估在兔眼中植入目前市售的具有方形光学元件边缘的3片和1片疏水性丙烯酸人工晶状体(IOL)的兔眼后后囊混浊(PCO)的结果。地点:美国犹他州盐湖城犹他大学John A. Moran眼科中心。方法:评估的三件式设计是AR40e(先进医疗光学公司)和MA60AC(爱尔康公司)。 1件式设计是SA60AT和SA30AT(Alcon,Inc.)。同一位外科医生以随机方式将9种晶状体植入18只荷兰带状有色兔子中。随访3周后,处死兔子,并从后方或Miyake-Apple的角度对去核的眼睛进行分析。中心PCO,外围PCO和Soemmering环形成的强度得分为0到4。Soemmering环形成的面积也根据所涉及的象限的数量得分为0到4。分析的其他参数是撕囊的人工晶状体前表面覆盖率,人工晶状体的定中心,固定和条纹的存在。后视结果与眼睛的组织病理学评估相辅相成。结果:从后视图分析的参数中,四组人工晶状体之间无统计学差异。当采用单件式设计时发生细胞向内生长,导致外周和中央PCO形成时,更可能从视触觉连接处开始,这在裂隙灯检查的临床随访过程中观察到,并通过肉眼和组织病理学分析证实无核的眼睛。结论:方形,截短的光学边缘是预防PCO的最重要的IOL设计功能。 1件式设计的视觉接触点似乎是截短的光学边缘的屏障效果不太有效的位置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号