首页> 外文期刊>Journal of cataract and refractive surgery >Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens material.
【24h】

Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens material.

机译:与眼内晶状体材料相关的分散的和内聚的眼科内窥镜手术设备的去除时间。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To investigate the removal times of ophthalmic viscosurgical devices (OVDs) with different intraocular lens (IOL) designs and materials. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA, and Heidelberg IOL & Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. METHODS: In a standardized laboratory setup, the Miyake-Apple posterior view video technique was used to evaluate OVD removal from capsular bags in human autopsy eyes implanted with poly(methyl methacrylate) (PMMA), silicone, and acrylic IOLs. The cohesive OVD ProVisc (sodium hyaluronate 1.0%) and the dispersive OVD Viscoat (sodium hyaluronate 3.0% and chondroitin sulfate 4.0%) were stained with fluorescein for better visualization. The open-sky preparation and an Alcon Series 20000 Legacy phaco machine with a flow rate of 25 mL/min and a vacuum setting of +500 mm Hg (maximum irrigation/aspiration) were used. The time needed for complete removal of the cohesive and dispersive OVDs with each IOL type was measured and analyzed statistically. RESULTS: The mean removal times for both OVDs were as follows: Alcon MZ60BD PMMA IOL-25.0 seconds +/- 3.7 (SD) (Viscoat), 15.9 +/- 6.9 seconds (ProVisc); Alcon AcrySof MA60BM IOL-35.5 +/- 10.0 seconds (Viscoat), 25.6 +/- 4.7 seconds (ProVisc); Chiron/Bausch & Lomb C1043 silicone IOL-46.5 +/- 10.5 seconds (Viscoat), 17.3 +/- 2.1 seconds (ProVisc); AMO SI-30 silicone IOL-33.5 +/- 3.1 seconds (Viscoat), 15.3 +/- 6.3 seconds (ProVisc); and Pharmacia 912 silicone IOL-18.3 +/- 5.8 seconds (Viscoat), 19.8 +/- 4.3 seconds (ProVisc). CONCLUSIONS: Differences in OVD removal times were detected. The removal time for the cohesive OVD correlated with the IOL material. Overall, the time needed for complete removal was significantly longer for the dispersive OVD than for the cohesive OVD.
机译:目的:研究具有不同人工晶状体(IOL)设计和材料的眼内镜手术器械(OVD)的去除时间。地点:美国南卡罗来纳州查尔斯顿市,南卡罗来纳州医科大学风暴眼研究所眼科和眼科治疗学和生物装置研究中心,以及鲁普雷希特-卡尔斯大学眼科的海德堡IOL和屈光外科研究组德国海德堡海德堡的地图方法:在标准化实验室设置中,使用Miyake-Apple后视视频技术评估植入了聚甲基丙烯酸甲酯(PMMA),硅树脂和丙烯酸人工晶体的尸检眼睛中囊袋中的OVD去除情况。内聚的OVD ProVisc(透明质酸钠1.0%)和分散的OVD Viscoat(透明质酸钠3.0%,硫酸软骨素4.0%)用荧光素染色,以便于观察。使用露天制剂和流速为25 mL / min且真空设定为+500 mm Hg(最大灌溉/抽吸)的Alcon Series 20000 Legacy phaco机器。测量并完全消除每种IOL类型的内聚性和分散性OVD所需的时间,并进行统计分析。结果:两种OVD的平均去除时间如下:Alcon MZ60BD PMMA IOL-25.0秒+/- 3.7(SD)(Viscoat),15.9 +/- 6.9秒(ProVisc); Alcon AcrySof MA60BM IOL-35.5 +/- 10.0秒(Viscoat),25.6 +/- 4.7秒(ProVisc); Chiron / Bausch&Lomb C1043硅树脂IOL-46.5 +/- 10.5秒(Viscoat),17.3 +/- 2.1秒(ProVisc); AMO SI-30硅树脂IOL-33.5 +/- 3.1秒(Viscoat),15.3 +/- 6.3秒(ProVisc);和Pharmacia 912有机硅IOL-18.3 +/- 5.8秒(Viscoat),19.8 +/- 4.3秒(ProVisc)。结论:检测到OVD去除时间的差异。粘性OVD的去除时间与IOL材料相关。总体而言,对于分散型OVD而言,完全除去所需的时间明显长于内聚性OVD。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号