首页> 外文期刊>Journal of cataract and refractive surgery >Laser in situ keratomileusis for high hyperopia (>5.0 diopters) using optimized aspheric profiles: Efficacy and safety
【24h】

Laser in situ keratomileusis for high hyperopia (>5.0 diopters) using optimized aspheric profiles: Efficacy and safety

机译:优化的非球面轮廓用于高度远视(> 5.0屈光度)的激光原位角膜磨镶术:疗效和安全性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) for high hyperopia using an excimer laser and optimized aspheric profiles. Setting: Vissum Corporation and Miguel Hernández University, Alicante, Spain, and Research Institute of Ophthalmology, Giza, Egypt. Design: Case series. Methods: Eyes of patients with high hyperopia or hyperopic astigmatism (spherical equivalent [SE] ≥5.64 diopters [D]) had uneventful LASIK with an aspheric optimized ablation profile centered on the corneal vertex using an Amaris 500 kHz excimer laser and a femtosecond platform for flap creation with a temporal hinge. Results: There was a significant improvement in uncorrected distance visual acuity 3 months postoperatively (P<.01), with no significant changes afterward (P=.72). At 6 months, the corrected distance visual acuity (CDVA) remained unchanged or improved in 90.48% of eyes; 2 eyes (9.52%) lost 2 lines of logMAR CDVA. The postoperative SE was within ±0.50 D of emmetropia in 70.37% of eyes. The LASIK enhancement rate at the end of the follow-up was 29.4%. Significant induction of corneal primary spherical aberration and coma was found with 6.0 mm pupils (P<.01). The safety index was 0.94 and the efficacy index, 0.85. Conclusion: Laser in situ keratomileusis for high hyperopia using optimized aspheric profiles requires further improvement in terms of safety but was still an effective and a predictable procedure. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:使用准分子激光和优化的非球面轮廓评估高度原发性远视的激光原位角膜磨镶术(LASIK)的临床效果。地点:Vissum Corporation和西班牙阿利坎特的MiguelHernández大学,以及埃及吉萨的眼科研究所。设计:案例系列。方法:使用Amaris 500 kHz准分子激光和飞秒平台对高度远视或远视散光(等效球面度[SE]≥5.64屈光度[D])患者的眼睛进行整平的LASIK,其非球面最佳消融轮廓位于角膜顶点中心。用颞枢纽创造皮瓣。结果:术后3个月未矫正远视力有明显改善(P <.01),此后无明显变化(P = .72)。 6个月时,矫正远视力(CDVA)在90.48%的眼睛中保持不变或有所改善; 2眼(9.52%)丢失了2行logMAR CDVA。术后SE在眼睛正视眼的±0.50 D以内,占70.37%。随访结束时的LASIK增强率为29.4%。在6.0 mm瞳孔中发现了明显的角膜初级球面像差和昏迷感(P <.01)。安全指数为0.94,功效指数为0.85。结论:使用优化的非球面轮廓对高度远视进行激光原位角膜磨镶术需要在安全性方面进一步改善,但仍是一种有效且可预测的程序。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号