PURPOSE: To study the effects of foldable acrylic and poly(methyl methacrylate) (PMMA) intraocular lens (IOL) implantation on posterior capsule opacification (PCO). SETTING: Department of Ophthalmology, Dokuz Eylul University School of Medicine, Izmir, Turkey. METHODS: This consecutive series comprised 157 eyes having phacoemulsification with implantation of a foldable acrylic IOL with rectangular optic edges and a 5.5 mm optic (AcrySof) (n = 80 eyes) or a PMMA IOL with rounded optic edges and 5.5 mm optic (n = 77). Evaluated were incidence, location, and degree of PCO. Mean postoperative follow-up was 17.8 months +/- 1.7 (SD) (range 16 to 22 months). RESULTS: Posterior capsule opacification occurred in 8.7% of eyes in the foldable acrylic IOL group and in 24.7% of eyes in the PMMA IOL group. The difference between the 2 groups was statistically significant (P < .01). Centrally located PCO was significantly lower in the acrylic group (P < .01). There were 3 eyes with severe PCO in the PMMA group and none in the acrylic group. Anterior capsule contraction and fibrosis were present in 4 eyes in the PMMA group but none in the acrylic group. Soemmering's ring cataract formation was detected in 3 eyes, all with the AcrySof IOL. CONCLUSION: In addition to its optic material and rectangular optic edges, the AcrySof IOL provides additional advantages in lowering the incidence of PCO compared with rounded-edge PMMA IOLs.
机译:目的:研究可折叠丙烯酸和聚甲基丙烯酸甲酯(PMMA)人工晶状体(IOL)植入对后囊混浊(PCO)的影响。地点:土耳其伊兹密尔Dokuz Eylul大学医学院眼科。方法:该连续系列包括157眼进行超声乳化,植入可折叠的丙烯酸人工晶状体,其具有矩形光学边缘和5.5 mm光学镜片(AcrySof)(n = 80眼)或PMMA IOL带有圆形光学边缘和5.5 mm光学镜片(n = 77)。评估的是PCO的发生率,位置和程度。术后平均随访时间为17.8个月+/- 1.7(SD)(范围16到22个月)。结果:可折叠丙烯酸人工晶体组中有8.7%的眼睛发生了后囊混浊,而PMMA人工晶体组中有24.7%的患者发生了后囊混浊。两组之间的差异具有统计学意义(P <.01)。丙烯酸基团位于中心的PCO明显较低(P <.01)。 PMMA组有3眼严重PCO,而丙烯酸组则无。在PMMA组中有4只眼出现前囊收缩和纤维化,而在丙烯酸组中没有。用AcrySof IOL在3只眼中检测到Soemmering的白内障形成。结论:除了具有光学材料和矩形光学边缘,与圆边PMMA IOL相比,AcrySof IOL还具有降低PCO发生率的其他优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号