首页> 外文期刊>Journal of cataract and refractive surgery >Comparison of posterior capsule opacification and glistenings with 2 hydrophobic acrylic intraocular lenses: 5- to 7-year follow-up
【24h】

Comparison of posterior capsule opacification and glistenings with 2 hydrophobic acrylic intraocular lenses: 5- to 7-year follow-up

机译:2种疏水性丙烯酸人工晶状体比较后囊混浊和闪耀:5至7年的随访

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Purpose: To compare posterior capsule opacification (PCO) and glistenings 5 to 7 years after cataract surgery with implantation of 2 hydrophobic acrylic intraocular lenses (IOLs) and evaluate the effects on corrected distance visual acuity (CDVA) and contrast sensitivity. Setting: St. Erik Eye Hospital, Stockholm, Sweden. Design: Randomized clinical trial. Methods: Cataract surgery with standard phacoemulsification was performed in 1 eye of patients. The patients were randomized to an Acrysof SA60AT (1-piece IOL group) or a Sensar AR40e (3-piece IOL group), both hydrophobic acrylic IOLs with a sharp-edged design. Five to 7 years postoperatively, retroillumination images were obtained and the PCO area and severity (area affected within the capsulorhexis and severity) were evaluated using computer software. High-contrast (100%) and low-contrast (2.5%) CDVAs were measured. The neodymium:YAG laser capsulotomy rates were recorded. Scheimpflug images were obtained to evaluate glistenings, which were graded subjectively at the slitlamp and quantified objectively by digital image analysis using computer software. Results: The study enrolled 80 patients. There were no significant differences in PCO between the 2 groups. The 3-piece IOL group had significantly fewer glistenings (P<.001). There was good correlation between the subjective grading of glistenings and objective computer-processed image grading. The glistenings were not correlated with IOL power, CDVA, or contrast sensitivity. Conclusions: There were no significant differences in PCO between the 2 acrylic hydrophobic IOLs 5 to 7 years postoperatively. The 1-piece IOL group developed more glistenings than the 3-piece IOL group. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:比较白内障手术后植入2个疏水性丙烯酸人工晶状体(IOL)的白内障手术后5至7年的后囊混浊(PCO)和闪耀,并评估其对矫正远视力(CDVA)和对比敏感度的影响。地点:瑞典斯德哥尔摩圣埃里克眼科医院。设计:随机临床试验。方法:对1只眼的患者行标准白内障超声乳化白内障手术。将患者随机分为Acrysof SA60AT(1件IOL组)或Sensar AR40e(3件IOL组),这两种疏水性丙烯酸IOL均采用锋利的设计。术后五至七年,获取后照图像,并使用计算机软件评估PCO面积和严重程度(在撕囊和严重程度内受影响的区域)。测量了高对比度(100%)和低对比度(2.5%)CDVA。记录钕:YAG激光囊切开术率。获得了Scheimpflug图像以评估闪光,这些图像在裂隙灯处主观地分级,并使用计算机软件通过数字图像分析客观地量化。结果:该研究招募了80名患者。两组之间的PCO没有显着差异。 3件式IOL组的闪光明显减少(P <.001)。闪光的主观等级与计算机处理的客观图像等级之间存在良好的相关性。闪光与IOL能力,CDVA或对比敏感性无关。结论:术后5至7年,两种丙烯酸类疏水性IOL之间的PCO没有显着差异。 1件式IOL组比3件式IOL组闪耀更多。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号