首页> 外文期刊>Journal of cataract and refractive surgery >Visual simulation through different intraocular lenses in patients with previous myopic corneal ablation using adaptive optics: Effect of tilt and decentration
【24h】

Visual simulation through different intraocular lenses in patients with previous myopic corneal ablation using adaptive optics: Effect of tilt and decentration

机译:使用自适应光学器件对近视性角膜消融患者通过不同的人工晶状体进行视觉模拟:倾斜和偏心的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate visual quality differences between intraocular lenses (IOLs) in patients with previous myopic laser ablations and assess the impact of IOL decentration and tilt on visual quality. Setting: University of Valencia, Burjassot, Spain. Design: Cohort study. Methods: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 1 aberration-correcting IOL (Acrysof IQ SN60WF), 1 aberration-free IOL (Akreos Adapt AO), and 1 spherical IOL (Triplato) under 5 IOL situations: centered, 0.2 mm and 0.4 mm decentered, and 2 degrees and 4 degrees tilted in eyes with simulated low or high myopic laser corneal ablations. Monocular distance visual acuity at 100%, 50%, and 10% contrast were measured. Results: Ten eyes of 10 patients were evaluated. When the IOLs were centered, the aberration-correcting IOL provided the best visual quality results in both groups. When the IOLs were misaligned, there was a decrease of visual quality with all simulated IOLs except the aberration-free IOL in the high myopia group. In the misaligned situations, all simulated IOLs obtained comparable visual quality results in both groups. Conclusions: The results suggest that in patients with previous myopic laser corneal ablation, aberration-correcting IOLs should be implanted. The decrease in visual quality when these IOLs are decentered or tilted demonstrates the importance of accurate implantation of these IOLs. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:评估先前近视激光消融患者的人工晶状体(IOL)之间的视觉质量差异,并评估IOL偏斜和倾斜对视觉质量的影响。地点:西班牙Burjassot的瓦伦西亚大学。设计:队列研究。方法:在5种IOL情况下,使用自适应光学视觉模拟器模拟1个像差校正IOL(Acrysof IQ SN60WF),1个无像差IOL(Akreos Adapt AO)和1个球面IOL(Triplato)的波前像差模式:在模拟的低度或高度近视激光角膜消融术中,眼睛居中,偏心0.2毫米和0.4毫米,倾斜2度和4度。测量了100%,50%和10%对比度下的单眼距离视敏度。结果:对10例患者的10眼进行了评估。当IOL居中时,像差校正IOL在两组中都提供了最佳的视觉质量结果。当IOL未对准时,在高度近视组中,除无像差IOL外,所有模拟IOL的视觉质量均下降。在未对准的情况下,两组的所有模拟IOL均获得了可比的视觉质量结果。结论:该结果表明,在有近视激光角膜切除术的患者中,应植入矫正像差的人工晶体。当这些IOL偏心或倾斜时,视觉质量的下降证明了正确植入这些IOL的重要性。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号