首页> 外文期刊>British journal of ophthalmology >Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simulator
【24h】

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simulator

机译:Akreos Adapt AO人工晶状体在采用自适应光学视觉模拟器测量的不同角膜轮廓患者中的视觉性能

获取原文
获取原文并翻译 | 示例

摘要

Aims: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. Methods: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. Results: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic ablation groups (p=0.06). All these groups achieved better results than the high hyperopic ablation group (p<0.001). At 50% and 10%, the best values of VA were obtained for the virgin corneas and for the low myopic and low hyperopic ablation groups (p>0.1, for both levels of contrast). Significant differences were found between these three corneal profiles and the other two corneal profiles (p<0.002 for high myopic and p<0.001 for high hyperopic, for both levels of contrasts). Conclusions: The results suggest that the aberrationfree IOL design gives an excellent visual performance for a range of corneal spherical aberrations that could correspond to patients with virgin corneas and patients in which the corneal spherical aberration has been slightly modified by a hyperopic or myopic laser ablation.
机译:目的:使用自适应光学视觉仿真技术,评估具有不同角膜轮廓的患者的无像差人工晶状体(IOL)的视觉性能。方法:使用crx1自适应光学视觉模拟器模拟无像差IOL结合五个角膜轮廓的原始像差模式:原始角膜和低度和高度近视消融以及低度和高度远视消融的角膜。对10位受试者的10只眼睛进行了评估,并测量了100%,50%和10%对比度的单眼远视力(VA)。结果:在100%的对比下,原始角膜,低度和高度近视消融和低度远视消融组之间的VA值无差异(p = 0.06)。与高度远视消融组相比,所有这些组均取得了更好的结果(p <0.001)。对于原始角膜以及低近视和低远视消融组,在50%和10%时可获得最佳VA值(两个对比水平p> 0.1)。在这三个对比水平上,这三个角膜轮廓与其他两个角膜轮廓之间存在显着差异(对于高度近视,p <0.002;对于高度远视,p <0.001)。结论:结果表明,无像差IOL设计对于一系列角膜球面像差可提供出色的视觉性能,这些视差可能对应于原始角膜患者和远视或近视激光消融对角膜球面像差进行了轻微矫正的患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号