Factors affecting rotation of a posterior chamber collagen copolymer toric phakic intraocular lens

机译:影响后房胶原共聚物复曲面晶状体人工晶状体旋转的因素

获取原文
获取原文并翻译 | 示例

摘要

Purpose: To evaluate the correlation between postoperative rotation of the toric Implantable Collamer Lens phakic intraocular lens (pIOL) and associated factors. Setting: Nagoya Eye Clinic, Nagoya, Japan. Design: Case series. Methods: The toric pIOL axis was analyzed by calculating the ocular internal cylinder power and axis from the total refractive cylinder and corneal astigmatism using vector analysis (Jaffe and Clayman method). The correlation between the toric pIOL rotation over 6 months postoperatively and the associated factors (ie, age, preoperative manifest refractive sphere, preoperative manifest spherical equivalent, mean keratometric power, axial length, toric pIOL intraoperative fixation angle, postoperative toric pIOL vault [distance between toric pIOL and anterior surface of crystalline lens], toric pIOL spherical power) were evaluated. Results: The mean age of the 34 patients (58 eyes) was 35.7 years ± 6.5 (SD). The mean rotation 6 months postoperatively was 4.82 ± 6.98 degrees (range 0.0 to 47.2 degrees). The intraoperative toric pIOL fixation angle and postoperative toric pIOL rotation were significantly correlated (Spearman rank correlation: P=.0096 and R 2 = 0.1140; multiple logistic regression analysis: P=.009). In the 1 eye with significant rotation (47.2 degrees), the toric pIOL was exchanged for a larger toric pIOL. Conclusions: A small toric pIOL rotation occurred during the 6-month follow-up. One cause of rotation could be the intraoperative fixation angle of the toric pIOL. A toric pIOL with a minimum intraoperative fixation angle should be used to prevent postoperative rotation. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:评估复曲面复曲面植入式人工晶状体晶状体人工晶状体(pIOL)术后旋转与相关因素之间的相关性。地点:日本名古屋名古屋眼科诊所。设计:案例系列。方法:通过矢量分析(Jaffe和Clayman方法),通过总屈光度数和角膜散光计算眼内屈光度数和轴,从而分析复曲面pIOL轴。术后6个月复曲面pIOL旋转与相关因素之间的相关性(即年龄,术前明显屈光球,术前明显球面等效物,平均角膜屈光度,轴向长度,复曲面pIOL术中固定角度,术后复曲面pIOL拱顶[复曲面复晶体和晶状体的前表面],复曲面复晶体的球形屈光度)。结果:34名患者(58眼)的平均年龄为35.7岁±6.5(SD)。术后6个月的平均旋转度为4.82±6.9​​8度(范围为0.0至47.2度)。术中复曲面pIOL固定角度与术后复曲面pIOL旋转呈显着相关(Spearman等级相关:P = .0096,R 2 = 0.1140;多元逻辑回归分析:P = .009)。在具有明显旋转(47.2度)的1只眼中,将复曲面pIOL更换为较大的复曲面pIOL。结论:在6个月的随访期间出现了小的复曲面pIOL旋转。旋转的原因之一可能是复曲面pIOL的术中固定角度。术中固定角度最小的复曲面pIOL应该用于防止术后旋转。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号