...
首页> 外文期刊>Journal of cataract and refractive surgery >Comparison of iris-claw and posterior chamber collagen copolymer phakic intraocular lenses in keratoconus
【24h】

Comparison of iris-claw and posterior chamber collagen copolymer phakic intraocular lenses in keratoconus

机译:圆锥角膜虹膜爪和后房胶原共晶状体人工晶状体的比较

获取原文
获取原文并翻译 | 示例

摘要

Purpose To evaluate the visual and refractive outcomes, predictability, and stability of phakic intraocular lens (pIOL) implantation in keratoconic eyes and compare the results of 2 pIOL models. Setting Vissum Instituto Oftalmologico, Alicante, Spain. Design Retrospective case series. Methods An iris-claw (Artiflex) or collagen copolymer posterior chamber pIOL (PC pIOL) (Implantable Collamer Lens) was implanted in eyes with stable keratoconus. The main outcome measures were postoperative changes from the preoperative manifest refraction, uncorrected (UDVA) and corrected (CDVA) distance visual acuities, corneal topography, and endothelial cell count. Alpins vectorial analysis was performed. Results Twenty eyes received an iris-claw pIOL and 28 eyes, a PC pIOL. The mean spherical equivalent was -9.31 diopters (D) ± 4.20 (SD) (range -20.75 to -2.75) preoperatively and -0.46 ± 0.88 D (range -3.25 to 1.00 D) postoperatively (P<.001). No patient lost lines of CDVA. The mean decimal UDVA was 0.08 ± 0.09 preoperatively and 0.71 ± 0.26 postoperatively and the mean decimal CDVA, 0.77 ± 0.24 and 0.87 ± 0.98, respectively (P<.001). The mean efficacy index was 0.90 ± 0.26 and the mean safety index, 1.19 ± 0.29. The mean efficacy index was not statistically different between the PC pIOL (0.88 ± 0.28) and the iris-claw pIOL (0.96 ± 0.22) (P=.058). Refraction was stable during the follow-up. Conclusions Phakic IOL implantation is a suitable refractive surgical option for stable keratoconus. It may be especially indicated for the management of high ametropia and showed good efficacy and safety. Refractive and keratometric stability was confirmed. Financial Disclosure No author has a financial or proprietary interest in any material or method mentioned.
机译:目的评估角膜圆锥形眼中有晶状体人工晶状体(pIOL)植入的视觉和屈光结果,可预测性和稳定性,并比较两种pIOL模型的结果。设置西班牙阿利坎特Oftalmologico的Vissum Instituto Oftalmologico。设计回顾案系列。方法将虹膜爪(Artiflex)或胶原蛋白共聚物后房pIOL(PC pIOL)(植入式Collamer Lens)植入具有稳定圆锥角膜的眼睛。主要结局指标为术前明显屈光,未矫正(UDVA)和矫正(CDVA)远视力,角膜地形图和内皮细胞计数的术后变化。进行了Alpins矢量分析。结果20眼接受虹膜爪状pIOL,28眼接受PC状虹膜。术前平均球镜当量为-9.31屈光度(D)±4.20(SD)(范围-20.75至-2.75),术后为-0.46±0.88 D(范围-3.25至1.00 D)(P <.001)。没有患者失去CDVA株系。术前平均十进制UDVA为0.08±0.09,术后平均为0.71±0.26,平均十进制CDVA分别为0.77±0.24和0.87±0.98(P <.001)。平均功效指数为0.90±0.26,平均安全指数为1.19±0.29。 PC pIOL(0.88±0.28)和虹膜爪pIOL(0.96±0.22)之间的平均疗效指数在统计学上无差异(P = .058)。随访期间屈光稳定。结论晶状体人工晶状体植入术是稳定圆锥角膜的合适屈光手术选择。特别适用于治疗高度屈光不正并显示出良好的疗效和安全性。确认了屈光度和角膜曲率稳定性。财务披露没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号