首页> 外文期刊>Journal of cataract and refractive surgery >Refractive outcomes of laser-assisted subepithelial keratectomy for myopia, hyperopia, and astigmatism using a 213 nm wavelength solid-state laser
【24h】

Refractive outcomes of laser-assisted subepithelial keratectomy for myopia, hyperopia, and astigmatism using a 213 nm wavelength solid-state laser

机译:213 nm波长固态激光对近视,远视和散光的激光辅助上皮下角膜切除术的屈光结果

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors. Setting: Private practice, Jersey, United Kingdom. Design: Case series. Methods: The LASEK was performed using a Pulzar Z1 213 nm solid-state laser. Manifest refraction and uncorrected (UDVA) and corrected (CDVA) distance visual acuities were measured preoperatively and 2 and 6 months postoperatively. Accuracy, safety, efficacy, and stability were assessed at 6 months. Results: The study enrolled 245 eyes (134 patients). The preoperative spherical equivalent (SE) refractive errors ranged from -9.50 to +6.50 diopters (D); 24 eyes had more than 2.50 D of astigmatism. At 6 months, 60.4% of eyes were within ±0.25 D of the intended SE, 89.4% were within ±0.50 D, and 97.9% were within ±1.00 D. No eye lost 2 or more lines of CDVA; 95.5% of eyes were unchanged or gained 1 line. The mean cylinder power decreased from -0.98 ± 1.17 D to -0.14 ± 0.28 DC at 6 months. The mean SE was unchanged over the follow-up period; -0.01 ± 0.57 D and -0.01 ± 0.55 D at 2 months and 6 months, respectively. Conclusion: Laser-assisted subepithelial keratectomy performed using the 213 nm wavelength solid-state laser was safe, accurate, and effective for the treatment of myopia, hyperopia, and astigmatism. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:研究使用213 nm固态激光对广泛的屈光不正进行激光辅助上皮下角膜切除术(LASEK)后的视觉和屈光结果。地点:英国泽西岛的私人诊所。设计:案例系列。方法:LASEK使用Pulzar Z1 213 nm固态激光器进行。术前以及术后2个月和6个月测量明显的屈光度和未矫正(UDVA)和矫正(CDVA)远视力。在6个月时评估准确性,安全性,疗效和稳定性。结果:该研究招募了245只眼(134例患者)。术前球面等效屈光不正在-9.50至+6.50屈光度(D)之间; 24只眼的散光超过2.50D。在6个月时,有60.4%的眼睛在预期SE的±0.25 D内,89.4%的眼睛在±0.50 D内,97.9%的眼睛在±1.00 D内。 95.5%的眼睛没有改变或获得1条线。 6个月时,平均气缸功率从-0.98±1.17 D降低至-0.14±0.28 DC。在随访期间,平均SE值保持不变;在2个月和6个月时分别为-0.01±0.57 D和-0.01±0.55D。结论:使用213 nm波长固态激光进行激光辅助上皮下角膜切除术安全,准确,有效,可治疗近视,远视和散光。财务披露:没有任何作者对所提及的任何材料或方法有财务或专有利益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号