首页> 外文期刊>Journal of cataract and refractive surgery >Influence of different acrylic intraocular lens materials on optical quality of vision in pseudophakic eyes.
【24h】

Influence of different acrylic intraocular lens materials on optical quality of vision in pseudophakic eyes.

机译:不同的丙烯酸人工晶状体材料对假晶状体眼的视觉光学质量的影响。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To analyze the effect of hydrophobic and hydrophilic acrylic intraocular lens (IOL) material on the optical quality in pseudophakic eyes with a clear posterior capsule and assess in vitro forward light scatter of these IOLs. SETTING: St. Thomas' Hospital, London, United Kingdom. DESIGN: Comparative case series. METHODS: Eyes with a hydrophobic or hydrophilic acrylic IOL and a clear posterior capsule within the central 4.0 mm at least 3 months postoperatively were identified from 2 ongoing studies. Data on 100% and 9% logMAR corrected distance visual acuities (CDVA) and total eye aberrations with a 4.0 mm pupil were collected. The 10% and 50% point-spread function (PSF) values of double-pass measurements were collected. In vitro forward light scattering was analyzed for the IOL models using a standardized laboratory technique. RESULTS: Twenty-eight eyes had hydrophilic IOLs, and 43 had hydrophobic IOLs. There was no significant difference in IOL power, postoperative spherical equivalent, or 100% logMAR CDVA between hydrophilic IOLs and hydrophobic acrylic IOLs. Nine percent logMAR CDVA (P=.000), 10% PSF (P=.005), 50% PSF (P=.008), and Zernike polynomial 4 (P=.000) were significantly different between the IOL groups. Although in vitro forward-scatter levels were low in both groups, hydrophilic IOLs had more forward scatter. CONCLUSIONS: Hydrophobic acrylic IOLs gave better low contrast visual acuity. Even within the acrylic subgroup, the optical quality varied significantly. The IOL material is an important factor influencing the optical quality of vision with different acrylic IOLs.
机译:目的:分析疏水性和亲水性丙烯酸人工晶状体(IOL)材料对具有透明后囊的假晶状体眼的光学质量的影响,并评估这些IOL的体外前向光散射。地点:英国伦敦圣托马斯医院。设计:比较案例系列。方法:从两项正在进行的研究中,鉴定出术后至少3个月内具有疏水性或亲水性丙烯酸人工晶状体和透明后囊在中央4.0 mm以内的眼睛。收集有关100%和9%logMAR校正的远视力(CDVA)以及瞳孔为4.0 mm的总眼像差的数据。收集了两次通过测量的10%和50%点扩展函数(PSF)值。使用标准实验室技术分析了IOL模型的体外前向光散射。结果:28只眼具有亲水性IOL,43只眼具有疏水性IOL。亲水性IOL和疏水性丙烯酸IOL之间的IOL功效,术后球当量或100%logMAR CDVA没有显着差异。 IOL组之间有9%的logMAR CDVA(P = .000),10%PSF(P = .005),50%PSF(P = .008)和Zernike多项式4(P = .000)有显着差异。尽管两组的体外前向散射水平均较低,但亲水性IOL的前向散射程度更高。结论:疏水丙烯酸IOLs具有更好的低对比度视敏度。即使在丙烯酸亚组中,光学质量也有很大差异。 IOL材料是影响不同丙烯酸IOL的视觉光学质量的重要因素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号