首页> 外文期刊>Journal of Clinical Pharmacy and Therapeutics >Increased digitalis-like immunoreactive substances in neonatal plasma measured using fluorescence polarization immunoassay.
【24h】

Increased digitalis-like immunoreactive substances in neonatal plasma measured using fluorescence polarization immunoassay.

机译:使用荧光偏振免疫分析法测定的新生儿血浆中洋地黄样免疫反应性物质增加。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To better define the reported increased digitalis-like immunoreactive substances (DLIS) in neonatal plasma, we studied the relation among plasma DLIS level, blank intensity (BLK-I) value at FPIA measurement and plasma total bilirubin level. METHODS: The DLIS levels were measured in 10 neonates with or without jaundice and 10 infants in good health, using fluorescence polarization immunoassay (FPIA) and microparticle enzyme immunoassay (MEIA). BLK-I value and plasma total bilirubin level were also measured simultaneously. RESULTS: In neonates with jaundice, DLIS using FPIA, BLK-I and total bilirubin level were 0.58 +/-0.13 ng/mL, 2598 +/- 408, and 17.98 +/- 1.13 mg/dL, respectively, before phototherapy, and 0.33 +/-0.06 ng/mL, 1886 +/- 237, and 15.16 +/- 2.07 mg/dL after phototherapy. Corresponding values in neonates without jaundice were (DLIS: 0.34 +/-0.04 ng/mL; BLK-I: 1,764 +/- 278; total bilirubin: 10.37 +/- 4.54 mg/dL); in healthy infants (0.12 +/-0.06 ng/mL, 400.7 +/- 4.6 and 0.42 +/- 0.13 mg/dL, respectively) and in healthy volunteers (0.10 +/-0.07 ng/mL, 403.1 +/- 8.4, and 0.58 +/- 0.30 mg/dL, respectively). Using MEIA, DLIS was not detected in 10 neonates, 10 infants and 20 healthy volunteers. CONCLUSIONS: A fluorescent compound related to bilirubin increased the BLK-I value in the measurement of neonatal plasma using FPIA. The fluorescence was not the result of endogenous digitalis-like factors.
机译:目的:为了更好地定义报道的新生儿血浆中增加的洋地黄样免疫反应物质(DLIS),我们研究了血浆DLIS水平,FPIA测量时的空白强度(BLK-I)值与血浆总胆红素水平之间的关系。方法:采用荧光偏振免疫测定法(FPIA)和微粒酶免疫测定法(MEIA)对10例有或没有黄疸的新生儿和10例身体健康的婴儿进行DLIS检测。还同时测量了BLK-1值和血浆总胆红素水平。结果:在黄疸的新生儿中,使用FPIA的DLIS,BLK-1和总胆红素水平分别为光疗前的0.58 +/- 0.13 ng / mL,2598 +/- 408和17.98 +/- 1.13 mg / dL。光疗后0.33 +/- 0.06 ng / mL,1886 +/- 237和15.16 +/- 2.07 mg / dL。无黄疸的新生儿的相应值为(DLIS:0.34 +/- 0.04 ng / mL; BLK-1:1,764 +/- 278;总胆红素:10.37 +/- 4.54 mg / dL);健康婴儿(0.12 +/- 0.06 ng / mL,400.7 +/- 4.6和0.42 +/- 0.13 mg / dL)和健康志愿者(0.10 +/- 0.07 ng / mL,403.1 +/- 8.4,和0.58 +/- 0.30 mg / dL)。使用MEIA,在10名新生儿,10名婴儿和20名健康志愿者中未检测到DLIS。结论:与胆红素有关的荧光化合物在使用FPIA测量新生儿血浆中可提高BLK-1值。荧光不是内源性洋地黄样因子的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号