首页> 外文期刊>Clinical biomechanics >Mechanical properties of the human Achilles tendon, in vivo.
【24h】

Mechanical properties of the human Achilles tendon, in vivo.

机译:人体跟腱的体内机械性能。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Ultrasonography has been widely applied for in vivo measurements of tendon mechanical properties. Assessments of human Achilles tendon mechanical properties have received great interest. Achilles tendon injuries predominantly occur in the tendon region between the Achilles-soleus myotendinous junction and Achilles-calcaneus osteotendinous junction i.e. in the free Achilles tendon. However, there has been no adequate ultrasound based method for quantifying the mechanical properties of the free human Achilles tendon. This study aimed to: 1) examine the mechanical properties of the free human Achilles tendon in vivo by the use of ultrasonography and 2) assess the between-day reproducibility of these measurements. METHODS: Ten male subjects had the Achilles tendon moment arm length, Achilles tendon cross sectional area and free Achilles tendon length determined. All subjects performed isometric plantarflexion ramp contractions to assess between-day reproducibility on two separate days. Simultaneous ultrasonography based measurements of Achilles-soleus myotendinous junction and Achilles-calcaneus osteotendinous junction displacement together with Achilles tendon force estimates yielded free Achilles tendon mechanical properties. FINDINGS: Free Achilles tendon maximal force, deformation and stiffness were 1924 (SD 229) N, 2.2 (SD 0.6) mm and 2622 (SD 534) N/mm on day 1. For between-day reproducibility there were no significant differences between days for free Achilles tendon mechanical properties. The between-day correlation coefficient and typical error percent were 0.81 and 5.3% for maximal Achilles tendon force, 0.85 and 11.8% for maximal Achilles tendon deformation and 0.84 and 8.8% for Achilles tendon stiffness respectively. Last, osteotendinous junction proximal displacement on average contributed with 71 (SD 12) % of proximal myotendinous junction displacement. INTERPRETATION: This study, for the first time, presents an ultrasonography based in vivo method for measurement of free AT mechanical properties. The method is applicable for evaluation of free human Achilles tendon mechanical properties in relation to training, injury and rehabilitation.
机译:背景:超声检查已广泛应用于肌腱力学特性的体内测量。对人类跟腱力学性能的评估引起了极大的兴趣。阿奇里斯腱损伤主要发生在阿奇里斯-比目鱼肌腱结与跟腱-跟骨骨腱结之间的肌腱区域,即游离的阿奇里斯腱。但是,没有足够的基于超声的方法来量化游离人类跟腱的机械性能。这项研究旨在:1)通过使用超声检查体内游离的人类跟腱的机械性能,以及2)评估这些测量值的日间可重复性。方法:确定10名男性受试者的跟腱力矩臂长,跟腱横截面积和游离跟腱长度。所有受试者均进行等角plant屈斜坡收缩,以评估两天之间的日间再现性。基于超声的同时测量跟腱-比目鱼肌腱连接处和跟腱-跟骨骨腱连接处的位移以及跟腱力估算值可得出游离的跟腱机械性能。结果:第一天的游离跟腱最大力,变形和刚度分别为1924(SD 229)N,2.2(SD 0.6)mm和2622(SD 534)N / mm。就一天之间的可重复性而言,两天之间没有显着差异免费的跟腱机械性能。日间最大跟腱力的日间相关系数和典型误差百分比分别为0.81和5.3%,最大跟腱变形的日间相关系数分别为0.85和11.8%,跟腱刚度的日相关系数和典型误差百分比分别为0.85和11.8%。最后,骨腱结近端移位平均占近端肌腱结移位的71(SD 12)%。解释:这项研究首次提出了一种基于超声的体内测量游离AT机械性能的方法。该方法适用于评估与训练,损伤和康复有关的游离人类跟腱力学性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号