BACKGROUND: The purpose of this study was to determine the plantar forefoot offloading efficacy of a new prefabricated vacuum-cushioned cast replacement system designed for foot ulcer treatment in neuropathic diabetic patients. METHODS: Fifteen diabetic subjects with peripheral neuropathy underwent in-shoe plantar pressure assessment while walking in five different footwear types: a standard vacuum-cushioned system with instantly moldable vacuum cushion and roller outsole, two modified vacuum-cushioned systems, one with flat surface vacuum cushion and one with flat outsole, a forefoot offloading shoe, and a control shoe. Regional peak pressures, pressure-time integrals, and inter-regional load transfers were calculated to determine the mechanical action of the footwear. Perceived walking comfort was tested using a 10-point visual analogue scale. FINDINGS: Forefoot peak pressures and pressure-time integrals were significantly lower (by 41-56%) in the vacuum-cushioned system compared to control. Compared to the forefoot offloading shoe, the vacuum-cushioned system showed significantly higher metatarsal head peak pressures, similar metatarsal head pressure-time integrals, and significantly lower hallux peak pressures and pressure-time integrals. A major transfer of forefoot load to the midfoot explained the offloading efficacy of the vacuum-cushioned system. Few significant differences were present between the modified and standard vacuum-cushioned systems. Perceived walking comfort was significantly higher in the vacuum-cushioned system (score 6.6) than in the forefoot offloading shoe (score 3.4). INTERPRETATION: The results showed that the vacuum-cushioned cast replacement system was effective in offloading the plantar forefoot of diabetic patients at risk for ulceration, although the contribution of the instantly moldable vacuum cushion and roller outsole were relatively small. The combined peak pressure, pressure-time integral and walking comfort results indicate that the vacuum-cushioned system may be a useful alternative for the forefoot offloading shoe in offloading the plantar diabetic forefoot.
机译:背景:本研究的目的是确定一种新型预制真空垫式石膏置换系统的足底前足卸载功效,该系统设计用于治疗神经性糖尿病患者的足溃疡。方法:十五名患有周围神经病变的糖尿病受试者在五种不同的鞋类中行走时进行了鞋内足底压力评估:具有立即成型的真空垫和滚轮外底的标准真空缓冲系统,两个改进的真空缓冲系统,一个具有平坦表面真空的系统坐垫和一个带平底的鞋底,一个前脚卸鞋和一个控制鞋。计算区域峰值压力,压力-时间积分和区域间负荷转移,以确定鞋类的机械作用。使用10点视觉模拟量表测试了感知的步行舒适度。结果:与对照相比,真空缓冲系统中的前脚峰值压力和压力时间积分显着降低(降低41-56%)。与前脚卸载鞋相比,真空缓冲系统显示出higher骨头的峰值压力明显更高,similar骨头的压力-时间积分相似,并且拇趾峰值压力和压力-时间积分明显更低。前脚负荷到中足的主要转移解释了真空缓冲系统的卸载功效。改进后的系统与标准真空缓冲系统之间几乎没有显着差异。真空缓冲系统(得分6.6)的感知步行舒适度明显高于前脚卸载鞋(得分3.4)。解释:结果表明,尽管可立即成型的真空垫和滚轮外底的贡献相对较小,但真空缓冲铸模置换系统可有效减轻患有溃疡风险的糖尿病患者的足底前掌。峰值压力,压力时间积分和步行舒适度的组合结果表明,真空缓冲系统对于减轻足底糖尿病前足的负担可能是前足卸鞋的有用选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号