首页> 外文期刊>Clinical biomechanics >Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density.
【24h】

Addition of a short central extension to surface cemented tibial trays in primary TKA: an in vitro study of the effect on initial fixation stability and its relationship to supporting bone density.

机译:在原发性TKA中向表面骨水泥型胫骨托增加短的中央延伸:对初始固定稳定性及其与支撑骨密度关系的体外研究。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Short central extensions which do not enter the tibial medullary canal are incorporated to cemented tibial components to increase initial stability in primary total knee arthroplasty. Their role in tibiae of differing preoperative mechanical quality has been little studied. METHODS: Twelve embalmed cadaveric tibiae were paired and divided into two groups, receiving a similar cemented tibial component with or without a non-cemented short central extension (10 mm diameter, 35 mm length). The specimens were subjected to 6000 cycles of a medially applied 1350 N load. Relative bone-tray displacements were measured and the evolution of inducible and permanent micromotions were computed. The apparent density of the cancellous bone under the tibial tray and at the area to support the extension was computed from computed tomography images of each specimen. FINDINGS: No significant differences between groups were detected for any parameters. For the group with extension, a significant negative linearcorrelation (P = 0.009, r(2) = 0.849) was found between the inducible tilt of the tray and the bone density at the zone of the extension. Also a trend towards a negative linear relation (P = 0.07, r(2) = 0.59) was observed for the same group between maximum subsidence and apparent density at the zone of the extension. INTERPRETATION: The study did not find that the addition of a non-cemented short central extension provides any overall improvement of the initial fixation stability. However, it was found that short extensions may enhance tilting stiffness of the bone-implant construct if bone of sufficient mechanical quality is located around its supporting area.
机译:背景:没有进入胫骨髓管的短中央延伸部分被合并到骨水泥接合的胫骨组件中,以增加初次全膝关节置换术的初始稳定性。对其术前机械质量不同的胫骨的作用尚未进行研究。方法:将十二个经过防腐处理的尸体胫骨配对并分为两组,分别接受相似的骨水泥胫骨组件,无论是否有非骨水泥短的中央延伸(直径10 mm,长度35 mm)。样品在中间施加的1350 N载荷下经受了6000次循环。测量相对的骨托盘位移,并计算诱导性和永久性微运动的演变。从每个标本的计算机断层扫描图像计算出胫骨托下方和支撑延伸区域的松质骨的表观密度。结果:对于任何参数,组间均未发现显着差异。对于具有延伸的组,在托盘的可诱导倾斜度与延伸区域的骨密度之间发现了显着的负线性相关性(P = 0.009,r(2)= 0.849)。对于最大沉降和延伸区域的表观密度之间的同一组,还观察到朝着负线性关系的趋势(P = 0.07,r(2)= 0.59)。解释:该研究未发现增加非骨水泥短中央延伸物不会对初始固定稳定性产生任何总体改善。然而,已经发现,如果具有足够机械质量的骨头位于其支撑区域周围,则短的延伸可以增强骨植入物构造的倾斜刚度。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号