首页> 外文期刊>Journal of Chromatography, Biomedical Applications >Determination of a novel selective inhibitor of type 1 5 alpha-reductase in human plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry
【24h】

Determination of a novel selective inhibitor of type 1 5 alpha-reductase in human plasma by liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry

机译:液相色谱-常压化学电离串联质谱法测定人血浆中新型1 5型α-还原酶选择性抑制剂

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

lA sensitive and specific assay of human plasma for the determination of (5 alpha,7 beta,16 beta)-16[(4-chlorophenyl)oxy]-4,7-dimethyl-4-aza-andronstan-3-one (I), a selective inhibitor of human type 1 5 alpha-reductase, has been developed. The method is based on high-performance liquid chromatography (HPLC) with tandem mass spectrometric (MS-MS) detection. The analyte (I) and internal standard, Proscar (II), were isolated from the basified biological matrix using a liquid-liquid extraction with methyl-tert.-butyl ether (MTBE). The organic extract was evaporated to dryness, the residue was reconstituted in mobile phase and injected into the HPLC system. The MS-MS detection was performed on a PE Sciex API III Plus tandem mass spectrometer using a heated nebulizer interface. Multiple reaction monitoring using the precursor-->product ion combinations of m/z 430-->114 and 373-->305 was used to quantify I and internal standard (II), respectively. The assay was validated in the concentration range of 0.5 to 500 ng/ml in human plasma. The precision of the assay, expressed as coefficient of variation (C.V.), was less than 7% over the entire concentration range, with adequate assay specificity and accuracy. The HPLC-MS-MS method provided sufficient sensitivity to completely map the 24 h pharmacokinetic time-course following a single 0.5 mg dose of I. (C) 1998 Elsevier Science B.V. All rights reserved. [References: 11]
机译:1A用于测定(5 alpha,7 beta,16 beta)-16 [(4-氯代苯基)氧基] -4,7-二甲基-4-氮杂-安达斯坦-3-酮(I ),是人类1 5型α-还原酶的选择性抑制剂。该方法基于具有串联质谱(MS-MS)检测的高效液相色谱(HPLC)。使用甲基叔丁基醚(MTBE)进行液-液萃取,从碱化的生物基质中分离出分析物(I)和内标Proscar(II)。将有机萃取液蒸发至干,将残留物在流动相中重构并注入HPLC系统。 MS-MS检测是在PE Sciex API III Plus串联质谱仪上使用加热的雾化器接口进行的。使用m / z 430-> 114和373-> 305的前体->产物离子组合进行的多反应监测分别用于定量I和内标(II)。该测定在人血浆中的浓度范围为0.5至500 ng / ml时得到验证。以变​​异系数(C.V.)表示的测定精度在整个浓度范围内均小于7%,具有足够的测定特异性和准确性。 HPLC-MS-MS方法提供了足够的灵敏度,可以完整地绘制出单剂量0.5 mg I后的24小时药代动力学过程。(C)1998 Elsevier Science B.V.保留所有权利。 [参考:11]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号