首页> 外文期刊>Journal of Chromatography, Biomedical Applications >Quantitation of itraconazole in rat heparinized plasma by liquid chromatography-mass spectrometry
【24h】

Quantitation of itraconazole in rat heparinized plasma by liquid chromatography-mass spectrometry

机译:液相色谱-质谱法测定大鼠肝素化血浆中伊曲康唑的含量

获取原文
获取原文并翻译 | 示例
           

摘要

A liquid chromatographic-mass spectrometric (LC-MS) assay was developed and validated for the determination of itraconazole (ITZ) in rat heparinized plasma using reversed-phase HPLC combined with positive atmospheric pressure ionization (API) mass spectrometry. After protein precipitation of plasma samples (0.1 mi) with acetonitrile containing nefazodone as an internal standard (I.S.), a 50-mul aliquot of the supernatant was mixed with 100 mul of 10 mM ammonium formate (pH 4.0). An aliquot of 25 mul of the mixture was injected onto a BDS Hypersil C-18 column (50 x 2 mm; 3 mum) at a how-rate of 0.3 ml/min. The mobile phase comprising of 10 mM ammonium formate (pH 4) and acetonitrile (60:40, v/v) was used in an isocratic condition, and ITZ was detected in single ion monitoring (SIM) mode. Standard curves were linear (r(2) greater than or equal to 0.994) over the concentration range of 4-1000 ng/ml. The mean predicted concentrations of the quality control (QC) samples deviated by less than 10% from the corresponding nominal values; the intra-assay and inter-assay precision of the assay were within 8% relative standard deviation. Both ITZ and I.S. were stable in the injection solvent at room temperature for at least 24 h. The extraction recovery of ITZ was 96%. The Validated assay was applied to a pharmacokinetic study of ITZ in rats following administration of a single dose of itraconazole (15 mg/kg). (C) 2001 Elsevier Science B.V. All rights reserved. [References: 15]
机译:建立了液相色谱-质谱(LC-MS)测定法,并通过反相HPLC和正大气压电离(API)质谱联用验证了大鼠肝素化血浆中伊曲康唑(ITZ)的测定。用含有奈法唑酮作为内标(I.S.)的乙腈沉淀血浆样品(0.1 mi)后,将50 mul等份的上清液与100 mul的10 mM甲酸铵(pH 4.0)混合。将25 mul混合物的等分试样以0.3 ml / min的流速注入BDS Hypersil C-18色谱柱(50 x 2 mm; 3 mum)。在等度条件下使用包含10 mM甲酸铵(pH 4)和乙腈(60:40,v / v)的流动相,并以单离子监测(SIM)模式检测ITZ。在4-1000 ng / ml的浓度范围内,标准曲线是线性的(r(2)大于或等于0.994)。质量控制(QC)样品的平均预测浓度与相应标称值的偏差小于10%;测定的测定内和测定间精度在相对标准偏差的8%以内。 ITZ和I.S.在室温下在注入溶剂中稳定至少24小时。 ITZ的提取回收率为96%。在单剂量伊曲康唑(15 mg / kg)给药后,将经过验证的测定方法应用于大鼠ITZ的药代动力学研究。 (C)2001 Elsevier Science B.V.保留所有权利。 [参考:15]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号