BACKGROUND: Apolipoprotein C-II and apolipoprotein C-III play an important and complex role in plasma triglycerides metabolism, respectively, as inhibitor and activator of lipoprotein lipase. Thus, they appear to be suitable markers for clinical studies of triglyceride-rich lipoproteins and related cardiovascular risk. Our aim was to evaluate, for routine analysis, the accuracy to quantify these apolipoprotein in human sera. METHODS: Precision (intra- and inter-run), limit of detection and quantification, linearity, common interferents (lipids, haemoglobin, bilirubin) and reference intervals were determined according to guidelines of the French Society of Clinical Biology and ISO Norm 5725 specifications. RESULTS: Intra- and inter-run CVs were respectively less than 5.0% and 7.5%. Linearities extended from 10.8 mg/L to 112.9 mg/L for apolipoprotein C-II and from 31.8 mg/L to 375.5 mg/L for apolipoprotein C-III. Haemolysis (up to 227.6 micromol/L haemoglobin) and lipemia (up to 19.3 mmol/L triglycerides) do not interfere, contrary to bilirubin, which has a positive effect above 350 micromol/L. Comparison of methods shows good agreement between immunoturbidimetric and electro-immunodiffusion methods for measuring apolipoprotein C-III in 62 samples within a wide range (n = 62, r = 0.954, y = 3.81 x -14.4). CONCLUSION: This study shows the reliability of these kits for measuring apolipoprotein C-II and apolipoprotein C-III in human sera, and their suitability for routine analysis.
机译:背景:载脂蛋白C-II和载脂蛋白C-III在血浆甘油三酸酯代谢中分别起着重要和复杂的作用,它们是脂蛋白脂肪酶的抑制剂和活化剂。因此,它们似乎是富含甘油三酸酯的脂蛋白和相关心血管风险的临床研究的合适标志物。我们的目标是评估常规血清中定量这些载脂蛋白的准确性,以进行常规分析。方法:根据法国临床生物学协会和ISO Norm 5725规范确定了精密度(批内和批间),检测和定量限,线性,常见干扰物(脂质,血红蛋白,胆红素)和参考区间。结果:批内和批间CV分别小于5.0%和7.5%。载脂蛋白C-II的线性从10.8 mg / L扩展到112.9 mg / L,载脂蛋白C-III的线性从31.8 mg / L扩展到375.5 mg / L。与胆红素相反,溶血(高达227.6 micromol / L的血红蛋白)和血脂(高达19.3 mmol / L的甘油三酸酯)没有干扰,而胆红素在350 micromol / L以上具有积极作用。方法的比较表明,在宽范围(n = 62,r = 0.954,y = 3.81 x -14.4)中测量62个样品中的载脂蛋白C-III的免疫比浊法和电免疫扩散法之间具有良好的一致性。结论:这项研究表明了这些试剂盒在人血清中测量载脂蛋白C-II和载脂蛋白C-III的可靠性,以及它们在常规分析中的适用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号