INTRODUCTION: Ablation electrode-tissue contact has been shown to be an important determinant of lesion size and safety during nonirrigated ablation but little data are available during irrigated ablation. We aimed to determine the importance of contact force during irrigated-tip ablation. METHODS AND RESULTS: Freshly excised hearts from 11 male pigs were perfused and superfused using fresh, heparinized, oxygenated swine blood in an ex vivo model. One-minute ablations were placed using one of 3 different power control strategies (impedance control-15 Omega target impedance drop, and 20 W or 30 W fixed power) and 3 different contact forces (2 g, 20 g, and 60 g) to give a grid of 9 ablation groups. The force sensing catheter (Tacticath, Endosense SA) was irrigated at 17 mL/min for all of the ablations. Of a total 101 ablations, no thrombus formation was noted but popping was seen in 17 lesions. The lesion depth and incidence of pops was 5.0 +/- 1.3 mm /0%, 5.0 +/- 1.6 mm /10% and 6.7 +/- 2.5 mm /45% for the 15 Omega, 20 W, and 30 W groups (P < 0.01), respectively, and 4.4 +/- 1.8 mm /3%, 5.8 +/- 1.6 mm /17% and 6.6 +/- 2.0 mm /37% for the 2 g, 20 g, and 60 g groups, respectively (P < 0.01). The impedance drop in the first 5 seconds was significantly correlated to catheter contact force: 9.7 +/- 9.9 Omega, 22.3 +/- 11.0 Omega, and 41.7 +/- 22.1 Omega, respectively, for the 2 g, 20 g, and 60 g groups (Pearson's r = 0.65, P < 0.01). CONCLUSION: Catheter contact force has an important impact on both ablation lesion size and the incidence of pops.
机译:简介:消融电极与组织的接触已被证明是非冲洗消融过程中病变大小和安全性的重要决定因素,但在冲洗消融过程中几乎没有可用的数据。我们旨在确定尖端消融过程中接触力的重要性。方法和结果:在离体模型中,使用新鲜的肝素化,含氧猪血对11只雄性猪的新鲜切除的心脏进行灌注和灌注。使用3种不同的功率控制策略(阻抗控制15 Omega目标阻抗下降以及20 W或30 W固定功率)和3种不同的接触力(2 g,20 g和60 g)之一放置一分钟消融给出9个消融组的网格。对于所有消融,以17 mL / min的速度冲洗力感应导管(Tacticath,Endosense SA)。在总共101例消融中,未发现血栓形成,但在17个病变中发现了爆裂。 15个Omega,20 W和30 W组的损伤深度和爆裂的发生率分别为5.0 +/- 1.3 mm /0%、5.0 +/- 1.6 mm / 10%和6.7 +/- 2.5 mm / 45%( P <0.01),对于2 g,20 g和60 g组,分别为4.4 +/- 1.8 mm /3%、5.8 +/- 1.6 mm / 17%和6.6 +/- 2.0 mm / 37%,分别为(P <0.01)。前5秒的阻抗下降与导管接触力显着相关:2 g,20 g和60分别为9.7 +/- 9.9Ω,22.3 +/- 11.0Ω和41.7 +/- 22.1Ω。 g组(皮尔森r = 0.65,P <0.01)。结论:导管接触力对消融灶的大小和爆裂的发生都有重要影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号