【24h】

Effects of mixing techniques and dentin moisture conditions on push-out bond strength of ProRoot MTA and Biodentine

机译:混合技术和牙本质水分条件对ProRoot MTA和Biodentine推出抗粘结强度的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objective: To evaluate the influence of manual and mechanical mixing techniques as well as the effects of moisture on the push-out bond strength of ProRoot MTA (Dentsply Tulsa Dental, Tulsa, OK, USA) and Biodentine (Septodont, Saint Maur des Fosses, France) to radicular dentin.Material and methods: Two hundred and forty dentin discs were assigned into three groups with respect to the moisture condition tested: (1) dry, (2) paper points, (3) wet. The discs were further divided into four subgroups according to the calcium silicate cements (CSCs) and mixing techniques used: (1) ProRoot MTA mixed manually, (2) ProRoot MTA mixed mechanically, (3) Biodentine mixed manually, and (4) Biodentine mixed mechanically. Bond strengths of the cements to root canal dentin were measured using a push-out test setup. The data were statistically analyzed using three-way ANOVA and Bonferroni post hoc test p=0.05.Results: The data indicated that the push-out bond strength values were significantly affected by CSCs, mixing techniques, and moisture conditions (p<0.001). Dry conditions caused a significant decrease in bond strength values for both CSCs (p<0.001). The mean bond strength of Biodentine was significantly higher than that of ProRoot MTA, regardless of the mixing techniques and moisture conditions (p<0.001). Mechanical mixing favored bond strength values statistically compared to manual mixing (p<.001).Conclusion: The mixing techniques and moisture conditions have an effect on the push-out bond strengths of ProRoot MTA and Biodentine. Dry samples and manual mixing of cements deteriorate the push-out bond strengths values.
机译:目的:评估手动和机械混合技术的影响以及水分对ProRoot MTA(Dentsply Tulsa Dental,塔尔萨,俄克拉荷马州,美国)和Biodentine(Septodont,Saint Maur des Fosses,材料和方法:相对于测试的湿度条件,将240个牙本质牙盘分为三组:(1)干燥,(2)纸尖,(3)湿润。根据所使用的硅酸钙水泥(CSC)和混合技术,将光盘进一步分为四个子组:(1)ProRoot MTA手动混合,(2)ProRoot MTA机械混合,(3)Biodentine手动混合和(4)Biodentine机械混合。使用推出试验装置测量水泥与牙根管牙本质的粘结强度。使用三效方差分析和Bonferroni事后检验对数据进行统计学分析,p = 0.05。结果:数据表明,出料粘结强度值受CSC,混合技术和湿度条件的影响显着(p <0.001)。干燥条件导致两种CSC的粘结强度值显着降低(p <0.001)。无论混合技术和湿度条件如何,Biodentine的平均粘结强度均显着高于ProRoot MTA的平均粘结强度(p <0.001)。与手动混合相比,机械混合在统计上更倾向于粘合强度值(p <.001)。结论:混合技术和湿度条件会影响ProRoot MTA和Biodentine的推出粘合强度。干样品和水泥的手动混合会降低顶出粘结强度值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号