首页> 外文期刊>Journal of biomedical materials research. Part B, Applied biomaterials. >Remaining unreacted methacrylate groups in resin-based composite with respect to sample preparation and storing conditions using micro-Raman spectroscopy.
【24h】

Remaining unreacted methacrylate groups in resin-based composite with respect to sample preparation and storing conditions using micro-Raman spectroscopy.

机译:关于树脂基复合材料中未反应的甲基丙烯酸酯基团,使用微拉曼光谱法进行样品制备和储存条件。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups 1 and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/-3.2%) and 54.7% (+/-5.2%), respectively (p < 0.0001). There was no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (p < 0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.
机译:这项研究的目的是使用显微拉曼光谱法,然后采用不同的样品制备程序和储存条件,来测量树脂基复合材料(RBC)的转化度(DC)。在标准模具中准备了90份Tetric EvoCeram样品(列支敦士登的Schaan的Ivoclar Vivadent),并用大功率LED蓝光固化装置Bluephase(列支敦士登的Schaan的Ivoclar Vivadent)固化了20 s。样品被分为八组。记录第1组和第2组的DC,不进行抛光或不进行抛光。从垂直切开的样本与“拆分”样本中记录第3组和第4组的DC。在室温和湿度,37 +/- 1摄氏度的90 +/- 2%湿度,37 +/- 1摄氏度的蒸馏水或缓冲温育培养基(BIM)中储存样品后,记录5-8组的DC )在37 +/- 1摄氏度下保持24小时。抛光和未抛光样品中DC的平均值分别为63.6%(+/- 3.2%)和54.7%(+/- 5.2%)(p <0.0001)。样品切片后DC无显着差异(p> 0.05)。将样品储存在BIM(76.8%+/- 2.1%)中后,获得的DC值明显高于蒸馏水(59.7%+/- 5.7%),极端湿度(60.3%+/- 3.9%)或在室温下(DC 63.6%+/- 3.2%)(p <0.001)。通过显微拉曼光谱法测量的RBC的DC可能会受到样品制备和存储条件差异的影响,从而难以将体外研究的数据推断为临床相关信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号