首页> 外文期刊>Journal of biomedical materials research. Part B, Applied biomaterials. >Wear in molded tibial inserts: knee simulator study of H1900 and GUR1050 polyethylenes.
【24h】

Wear in molded tibial inserts: knee simulator study of H1900 and GUR1050 polyethylenes.

机译:穿入胫骨模制件中:H1900和GUR1050聚乙烯的膝盖模拟器研究。

获取原文
获取原文并翻译 | 示例

摘要

Hi-fax 1900 tibial inserts were used in the IB-1 total knee replacement (TKR) beginning 1978, soon followed by the AGC design. Such direct compression molded (DCM) inserts was relatively immune to oxidation. Unfortunately the Hi-fax 1900 resin (H1900) was taken off the market in year 2004. As an alternate, GUR1050 was introduced in the Vanguard TKR. However there appeared to be little or no wear comparisons of molded inserts. Therefore the study aim was to compare wear performance of GUR1050 to the historical H1900. The hypothesis was that Hi-fax and GUR1050 would show comparable wear performance. The Vanguar was a posterior-cruciate sacrificing design (Biomet Inc.). All tibial inserts were sterilized by gamma-radiation (3.2 Mrad) under argon. A 6-channel, displacement-controlled knee simulator was used with serum lubricant (protein concentration 20 mg/mL). Wear assessments were by gravimetric methods and linear regression techniques. The gross weight-loss trends over 2.5 Mc duration demonstrated excellent linear behavior with good agreement between TKR sets (<+/-10%). Fluid sorption artifacts in control represented less than 5% of gross wear magnitudes. Thus suitable corrections could be made in determining net wear. The H1900 and GUR1050inserts demonstrated net wear-rates of 3.6 and 3.4 mm(3)/Mc, respectively. This difference was not found to be statistically significant. This wear study demonstrated that GUR1050 inserts were indistinguishable from the Hi-fax 1900 in terms of laboratory wear performance, proving our hypothesis. Given the excellent clinical history of DCM Hi-fax 1900, the GUR1050 should be an ideal candidate for TKR.
机译:从1978年开始,Hi-fax 1900胫骨插入物用于IB-1全膝关节置换(TKR),随后进行了AGC设计。这种直接压模(DCM)插件相对抗氧化。不幸的是,Hi-fax 1900树脂(H1900)于2004年投放市场。作为替代,GUR1050被引入Vanguard TKR。然而,模制刀片的磨损似乎很少或没有。因此,研究目的是将GUR1050的磨损性能与历史H1900进行比较。假设是Hi-fax和GUR1050将表现出可比的磨损性能。 Vanguar是一种后十字牺牲设计(Biomet Inc.)。所有胫骨插入物均在氩气下通过伽马射线辐射(3.2 Mrad)灭菌。 6通道,位移控制的膝部模拟器与血清润滑剂(蛋白质浓度20 mg / mL)一起使用。磨损评估是通过重量分析法和线性回归技术进行的。在2.5 Mc持续时间内的总减肥趋势显示出出色的线性行为,并且TKR组之间具有良好的一致性(<+/- 10%)。对照中的流体吸附伪像占总磨损量的不到5%。因此,可以在确定净磨损时进行适当的校正。 H1900和GUR1050刀片的净磨损率分别为3.6和3.4 mm(3)/ Mc。没有发现这种差异具有统计学意义。这项磨损研究表明,GUR1050刀片在实验室磨损性能方面与Hi-fax 1900并无区别,证明了我们的假设。鉴于DCM Hi-fax 1900的出色临床历史,GUR1050应该是TKR的理想选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号