Having established dimensional and mechanical characteristics, the resistances to sliding (RS) were measured in vitro for various archwires against stainless steel brackets. Using stainless steel ligatures, a constant normal force (300g) was maintained while second-order angulation (#theta#) was varied from -12 deg to +12 deg. Using miniature bearings to simulate contiguous teeth, five experiments each were run in the dry or wet states with human saliva at 34 deg C as a function of four archwire alloys, five interbracket distances, and two bracket engagements. Outcomes were objectively analyzed to establish when #theta#=0, and the relative contact angles (#theta#r) were re-plotted. Critical contact angles (#theta#c) that were determined via experimentation were in good agreement with theory. Slopes and y-intercepts were tabulated from linear regression equations of RS against #theta# plots in both the passive (#theta# <=#theta#_c) and active (#theta#>=#theta#_c) configurations, for which #theta#=#theta#+c identified the boundary between classical friction and binding phenomena. Stiffer archwires and shorter interbracket distances exacerbated binding, whereas, once corrected for differing bracket engagement, RS was independent of slot dimension. Unlike earlier results in the passive configuration, in the active configuration couples comprised of titanium alloys (NiTi and (#beta#-Ti) had higher RS values in the wet versus the dry state. For those archwire alloys evaluated, two empirical expressions were adduced that comprise the binding component, the yield strength or elastic limit, and the beam length, which implicitly represent the stiffness, flexibility, and interbracket distance.
机译:建立了尺寸和机械特性后,在体外测量了各种弓丝相对于不锈钢支架的滑动阻力(RS)。使用不锈钢绑扎带,可以保持恒定的法向力(300g),而二阶角度(#theta#)从-12度到+12度变化。使用微型轴承来模拟连续的牙齿,每个实验都在干燥或湿润状态下进行,其中人唾液在34摄氏度下作为四种弓丝合金,五个支架间距离和两个支架接合的函数,在干燥或湿润状态下进行。客观分析结果以确定何时#theta#= 0,并重新绘制相对接触角(#theta#r)。通过实验确定的临界接触角(#theta#c)与理论吻合良好。斜率和y轴截距是通过RS的线性回归方程相对于被动(#theta#<=#theta#_c)和主动(#theta#> =#theta#_c)配置中的#theta#图绘制的, #theta#=#theta#+ c识别了经典摩擦和约束现象之间的边界。更坚硬的弓丝和更短的支架间距离加剧了结合,而一旦针对不同的支架接合进行了校正,RS便与插槽尺寸无关。不同于早期的被动配置结果,在主动配置中,由钛合金(NiTi和(#beta#-Ti)组成的对在湿态和干态下具有较高的RS值,对于评估的弓丝合金,得出了两个经验表达式包括粘合成分,屈服强度或弹性极限以及梁的长度,它们隐含地表示刚度,柔韧性和支架间的距离。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号