The purpose of this study was to investigate corrosion resistance of a laser spot-welded joint of NiTi alloy wires using potentiodynamic tests in Hank's solution at different PH values and the PH 7.4 NaCl solution for different Cl- concentrations. Scanning electron microscope observations were carried out before and after potentiodynamic tests. The composition of a laser spot-welded joint and base metal were characterized by using an electron probe microanalyzer. The results of potentiodynamic tests showed that corrosion resistance of a laser spot-welded joint of NiTi alloy wire was better than that of base metal, which exhibited a little higher breakdown potential and passive range, and a little lower passive current density. Corrosion resistances of a laser spot-welded joint and base metal decreased with increasing of the Cl- concentration and PH value. The improvement of corrosion resistance of the laser spot-welded joint was due to the decrease of the surface defects and the increase of the Ti/Ni ratio.
机译:这项研究的目的是通过在不同pH值的Hank溶液和不同Cl-浓度的PH 7.4 NaCl溶液中使用电位动力学试验研究NiTi合金丝的激光点焊接头的耐腐蚀性。在电位动力学试验之前和之后进行扫描电子显微镜观察。通过使用电子探针显微分析仪对激光点焊接头和贱金属的成分进行了表征。电位动力学测试结果表明,NiTi合金丝的激光点焊接头的耐蚀性优于贱金属,其击穿电位和无源范围稍高,而无源电流密度则较低。激光点焊接头和母材的耐蚀性随Cl浓度和PH值的增加而降低。激光点焊接头的耐腐蚀性的提高是由于表面缺陷的减少和Ti / Ni比的增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号