首页> 外文期刊>The Journal of Bone and Joint Surgery. American Volume >Comparison of Bone Mineral Density Between Porous Tantalum and Cemented Tibial Total Knee Arthroplasty Components
【24h】

Comparison of Bone Mineral Density Between Porous Tantalum and Cemented Tibial Total Knee Arthroplasty Components

机译:多孔钽与骨水泥胫骨全膝关节置换组件骨矿物质密度的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Background: Porous tantalum was recently Introduced as a metallic implant material for total knee arthroplasty. Its porosity, low modulus of elasticity, and high frictional characteristics were expected to provide physiologic load transfer and relative preservation of bone stock. However, to our knowledge, the effect of a Trabecular Metal tibial component on bone mineral density has not been reported. The purpose of the present study was to compare the peri prosthetic bone mineral density between patients managed with uncemented Trabecular Metal and cemented tibial components. Methods: Twenty-eight knees receiving a Trabecular Metal tibial component and twenty-eight knees receiving a cemented cobalt-chromium tibial component had dual x-ray absorptiometry scans at two weeks preoperatively and at two weeks and six, twelve, eighteen, and twenty-four months postoperatively, to assess periprosthetic bone mineral density. All of the operations were performed by one surgeon through a medial parapatellar approach. Results: None of the differences between the two groups in terms of preoperative bone mineral density in the femoral neck, wrist, lumbar spine, or knee were significant. In both groups, the bone mineral density in the tibia decreased postoperatively. However, the postoperative decrease in bone mineral density in the lateral aspect of the tibia was significantly less in knees with Trabecular Metal components than in knees with cemented tibial components at twenty-four months (mean and standard deviation, -6.7% +- 22.9% compared with -36.8% +- 24.2%; p = 0.002). At twenty-four months postoperatively, there was no significant difference between the two groups in terms of the Knee Society score, range of motion of the knee, or bone mineral density in the lumbar spine. No prosthetic migration or periprosthetic fracture was detected in either group. Conclusions: The decrease in bone mineral density of the lateral tibial plateau was less in knees with a Trabecular Metal tibial component following total knee arthroplasty than in knees with a cemented tibial component. Additional research is needed to determine whether long-term clinical benefits are realized with the use of porous tantalum tibial components for total knee arthroplasty. Level of Evidence: Therapeutic Level II. See Instructions to Authors for a complete description of levels of evidence.
机译:背景:多孔钽最近被用作全膝关节置换术的金属植入材料。预期它的孔隙率,低弹性模量和高摩擦特性可提供生理负荷转移和骨料的相对保存。然而,据我们所知,尚未报道骨小梁金属胫骨组件对骨矿物质密度的影响。本研究的目的是比较使用非骨水泥小梁金属和骨水泥胫骨组件治疗的患者的假体周围骨密度。方法:二十八膝接受小梁金属胫骨组件,二十八膝接受骨钴钴铬胫骨组件,分别在术前两周和两周分别进行双X线骨密度仪扫描,分别为六,十二,十八,二十二。术后四个月,以评估假体周围的骨矿物质密度。所有手术均由一名外科医生通过pat骨内侧入路进行。结果:两组在术前股骨颈,手腕,腰椎或膝盖的骨矿物质密度方面无显着差异。在两组中,胫骨的骨矿物质密度在术后均降低。但是,在二十四个月时,使用小梁金属组件的膝关节胫骨外侧骨矿物质密度的降低明显少于使用胶结胫骨组件的膝关节(均值和标准差,-6.7%+-22.9%则为-36.8%+-24.2%; p = 0.002)。术后24个月,两组在膝关节学会评分,膝关节活动范围或腰椎骨矿物质密度方面无显着差异。两组均未检测到假体迁移或假体周围骨折。结论:在全膝关节置换术后,使用小梁金属胫骨组件的膝关节,胫骨外侧平台的骨矿物质密度的降低要比使用胶结胫骨组件的膝盖少。需要进行更多的研究以确定使用多孔钽胫骨组件进行全膝关节置换术是否能实现长期临床益处。证据级别:治疗级别II。有关证据水平的完整说明,请参见《作者须知》。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号